• <menuitem id="qllo0"><input id="qllo0"></input></menuitem>
    <thead id="qllo0"></thead><form id="qllo0"><meter id="qllo0"></meter></form>
  • 參數(shù)資料
    型號(hào): FS1501-9EPD8B1
    元件分類: 電源模塊
    英文描述: 1-OUTPUT 100 W DC-DC REG PWR SUPPLY MODULE
    封裝: METAL, CASE S02, MODULE
    文件頁(yè)數(shù): 4/31頁(yè)
    文件大小: 633K
    代理商: FS1501-9EPD8B1
    Cassette Style
    100 Watt DC-DC Converters
    S Series
    Edition 1/01.2000
    12/31
    Thermal Considerations
    If a converter is located in free, quasi-stationary air (con-
    vection cooling) at the indicated maximum ambient tem-
    perature
    TA max (see table: Temperature specifications) and
    is operated at its nominal input voltage and output power,
    the temperature measured at the
    Measuring point of case
    temperature TC (see: Mechanical Data) will approach the
    indicated value
    TC max after the warm-up phase. However,
    the relationship between
    TA and TC depends heavily on the
    conditions of operation and integration into a system. The
    thermal conditions are influenced by input voltage, output
    current, airflow and temperature of surrounding compo-
    nents and surfaces.
    TA max is therefore, contrary to TC max,
    an indicative value only.
    Caution: The installer must ensure that under all operat-
    ing conditions
    TC remains within the limits stated in the
    table:
    Temperature specifications.
    Notes: Sufficient forced cooling or an additional heat sink
    allows
    TA to be higher than 71
    °C (e.g. 85°C) if T
    C max is not
    exceeded.
    For -7 or -9 units at an ambient temperature
    TA of 85
    °C with
    only convection cooling, the maximum permissible current
    for each output is approx. 40% of its nominal value as per
    figure.
    0
    0.1
    0.2
    0.3
    0.4
    0.5
    0.6
    0.7
    0.8
    50
    60
    70
    80
    90
    100
    Io/Io nom
    TA [°C]
    0.9
    1.0
    Forced cooling
    05089
    TA min
    TC max
    Convection cooling
    Fig. 7
    Output current derating versus temperature for -7 and -9
    units.
    Thermal Protection
    A temperature sensor generates an internal inhibit signal
    which disables the outputs if the case temperature exceeds
    TC max. The outputs are automatically re-enabled if the tem-
    perature drops below this limit.
    It is recommended that continuous operation under simul-
    taneous extreme worst case conditions of the following
    three parameters be avoided: Minimum input voltage,
    maximum output power and maximum temperature.
    Output Protection
    Each output is protected against overvoltage which could
    occur due to a failure of the control circuit by means of a
    voltage suppressor diode which, under worst case condi-
    tions, may become a short circuit. The suppressor diodes
    are not designed to withstand externally applied over-
    voltages. Overload at any of the two outputs will cause a
    shut-down of both outputs. A red LED indicates the over-
    load condition.
    Output Voltage Regulation of Single or Double Output
    Modules with Outputs 1 and 2 Connected in Series
    Uo
    Uo nom
    0.98
    0.5
    0
    0.5
    1.0
    Io1
    IoL
    Io
    Io nom
    05068
    Fig.8
    Uo1 vs. Io1 (typ.) of single output units
    Parallel or Series Connection of Units
    Single or double output units with equal nominal output volt-
    age can be connected in parallel without any precautions
    using option T.
    With option T (current sharing), all units share the current
    approximately equally.
    Single output units and/or main and second outputs of dou-
    ble output units can be connected in series with any other
    (similar) output.
    Note: Parallel connection of double output units should al-
    ways include both, main and second output to maintain
    good regulation of both outputs.
    Not more than 5 units should be connected in parallel.
    Series connection of second outputs without involving their
    main outputs should be avoided as regulation may be poor.
    The maximum output current is limited by the output with
    the lowest current limitation if several outputs are con-
    nected in series.
    相關(guān)PDF資料
    PDF描述
    FS1601-7EPD6TB1 1-OUTPUT 100 W DC-DC REG PWR SUPPLY MODULE
    FS1601-7EPD8T 1-OUTPUT 100 W DC-DC REG PWR SUPPLY MODULE
    FS1601-7EPD9TB2 1-OUTPUT 100 W DC-DC REG PWR SUPPLY MODULE
    FS1601-7EPDDTB1 1-OUTPUT 100 W DC-DC REG PWR SUPPLY MODULE
    FS1601-7ERD3TB1 1-OUTPUT 100 W DC-DC REG PWR SUPPLY MODULE
    相關(guān)代理商/技術(shù)參數(shù)
    參數(shù)描述
    FS1501-9ER 制造商:Power-One 功能描述:DCDC - Bulk
    FS150-20 制造商:JAMECO VALUEPRO 功能描述:Test Leads Breadboard 20 Pack 5.9 Inch (150mm) Wire Pin Cont
    FS150AR 制造商:Hammond Power Solutions 功能描述:Transformer, Control, 1ph, 150VA, 600-12x24V, 60Hz
    FS150K.5AB3 制造商:TE Connectivity 功能描述:
    FS150R06KE3 功能描述:IGBT 模塊 IGBT MODULES 600V RoHS:否 制造商:Infineon Technologies 產(chǎn)品:IGBT Silicon Modules 配置:Dual 集電極—發(fā)射極最大電壓 VCEO:600 V 集電極—射極飽和電壓:1.95 V 在25 C的連續(xù)集電極電流:230 A 柵極—射極漏泄電流:400 nA 功率耗散:445 W 最大工作溫度:+ 125 C 封裝 / 箱體:34MM 封裝: