  • 參數(shù)資料
    型號(hào): FRS-R-350
    元件分類: 保險(xiǎn)絲
    英文描述: Fuse
    中文描述: 保險(xiǎn)絲
    文件頁(yè)數(shù): 1/3頁(yè)
    文件大?。?/td> 32K
    代理商: FRS-R-350
    11-1-00
    A00115
    Fusetron
    Dual-Element, Time-Delay Fuses
    Class RK5 –– 600 Volt
    FRS-R
    65-600A
    Form No. FRS-R 70-600
    Page 1 of 3
    BIF Doc #1018
    Bussmann
    Catalog Symbol:
    FRS-R
    Dual-Element, Time-Delay – 10 seconds (minimum) at 500%
    rated current
    Current-Limiting
    Ampere Rating:
    65 to 600 Amperes
    Voltage Rating:
    600 Volts AC (or less)
    Interrupting Rating:
    200,000A RMS Sym.
    DC Ratings (20,000AIC @ 300 Vdc)
    Agency Approvals:
    U.L. Listed, Std. 248-12, Class RK5, Guide J DDZ, File E4273
    CSA Certified, C22.2 No. 248.12, Class 1422-01, File 53787
    Catalog Numbers
    FRS-R-65
    FRS-R-125
    FRS-R-70
    FRS-R-135
    FRS-R-75
    FRS-R-150
    FRS-R-80
    FRS-R-175
    FRS-R-85
    FRS-R-200
    FRS-R-90
    FRS-R-225
    FRS-R-100
    FRS-R-250
    FRS-R-110
    FRS-R-275
    FRS-R-300
    FRS-R-325
    FRS-R-350
    FRS-R-400
    FRS-R-450
    FRS-R-500
    FRS-R-600
    Fuse Reducers For Class R Fuses
    Desired
    Fuse (Case)
    Size
    100A
    100A
    200A
    100A
    200A
    400A
    Catalog Number
    (Pairs)
    600V
    No. 2621-R
    No. 2641-R
    No. 642-R
    No. 2661-R
    No. 2662-R
    No. 2664-R*
    Equipment
    Fuse Clips
    200A
    400A
    600A
    *Single reducer only (pair not required).
    For additional information, see BIF Document 1118.
    General Information:
    Provides motor overload, ground fault and short-circuit
    protection. When used in circuits subject to surge currents
    such as those caused by motors, transformers and other
    inductive components, these fuses can be sized close to
    full-load amperes to give maximum overcurrent protection.
    The time-delay feature makes it possible to use fuse ampere
    ratings which are much smaller than those of non-time-delay
    fuses. Considerable cost saving occurs by permitting the use
    of smaller size switches, panels and fuses themselves.
    Provides a good degree of short-circuit protection (greater
    current-limitation) to help protect downstream components
    from high fault currents.
    Gives motor running back-up protection to motors without
    extra costs.
    Helps protect motors against burnout from overloads and
    single phasing when sized properly.
    Simplifies and improves blackout prevention (selective
    coordination ratios).
    Dual-element fuses can be applied in circuits subject to
    temporary motor overloads and surge currents to provide
    both high-performance, short-circuit and overload protection.
    Carton Quantity and Weight
    Ampere
    Ratings
    65–100
    101–200
    201–400
    401–600
    *Weight per carton.
    Carton
    Qty.
    1
    1
    1
    1
    Weight*
    Lbs.
    0.54
    1.22
    3.00
    5.00
    Kg.
    0.245
    0.544
    1.359
    2.268
    A
    B
    Dimensional Data
    Fuseblocks – Class R Catalog Numbers
    (Clip Retaining Spring Standard, Suffix “R”)
    Terminal Type (Suffix No.)
    Box Lug w/
    Reinforced Clip
    Basic
    Catalog
    Number
    R60100-1
    R60100-2
    R60100-3
    R60200-1
    R60400-1
    R60600-1
    Amps
    65
    to
    100
    to 200
    to 400
    to 600
    For additional information on the R600 Series fuseblocks, refer to
    BIF Document 1111.
    Poles
    1
    2
    3
    1
    1
    1
    CU only
    COR
    COR
    COR
    CR
    CR
    CR
    CR
    CR
    CR
    Dimensions
    (inches)
    Ampere Ratings
    65-100
    110-200
    225-400
    450-600
    A
    B
    7.88 (± 0.062)
    9.63 (± 0.062)
    11.63 (± 0.094)
    13.38 (± 0.094)
    1.11 (± 0.020)
    1.61 (± 0.020)
    2.34 (± 0.020)
    2.88 (± 0.020)
    CE logo denotes compliance with European Union Low Voltage Directive
    (50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact
    Bussmann Application Engineering at 636-527-1270 for more information.
    To obtain information for 0-60 Amps, access BIF # 1017
    相關(guān)PDF資料
    PDF描述
    FRS-R-4 Fuse
    FRS-R-40 Fuse
    FRS-R-400 Fuse
    FRS-R-45 Fuse
    FRS-R-450 Fuse
    相關(guān)代理商/技術(shù)參數(shù)
    參數(shù)描述
    FRS-R-35ID 功能描述:保險(xiǎn)絲 FUSETRON DUAL-ELEMT CLASS RK5 INDICATI RoHS:否 制造商:Littelfuse 產(chǎn)品:Surface Mount Fuses 電流額定值:0.5 A 電壓額定值:600 V 保險(xiǎn)絲類型:Fast Acting 保險(xiǎn)絲大小/組:Nano 尺寸:12.1 mm L x 4.5 mm W 安裝風(fēng)格: 端接類型:SMD/SMT 系列:485
    FRSR4 制造商:Schneider Electric 功能描述:Class RK5 4A 600V Fuse (25414-00210)
    FRS-R-4 功能描述:保險(xiǎn)絲 600V 4A Dual Elemtent Time Delay RoHS:否 制造商:Littelfuse 產(chǎn)品:Surface Mount Fuses 電流額定值:0.5 A 電壓額定值:600 V 保險(xiǎn)絲類型:Fast Acting 保險(xiǎn)絲大小/組:Nano 尺寸:12.1 mm L x 4.5 mm W 安裝風(fēng)格: 端接類型:SMD/SMT 系列:485
    FRS-R-4/10 功能描述:保險(xiǎn)絲 600V .4A Dual Elemtent Time Delay RoHS:否 制造商:Littelfuse 產(chǎn)品:Surface Mount Fuses 電流額定值:0.5 A 電壓額定值:600 V 保險(xiǎn)絲類型:Fast Acting 保險(xiǎn)絲大小/組:Nano 尺寸:12.1 mm L x 4.5 mm W 安裝風(fēng)格: 端接類型:SMD/SMT 系列:485
    FRSR40 制造商:Schneider Electric 功能描述:Class RK5 40A 600V Fuse (25414-00370)
    <thead id="8rzwn"><sup id="8rzwn"><thead id="8rzwn"></thead></sup></thead>
  • <thead id="8rzwn"><div id="8rzwn"><tfoot id="8rzwn"></tfoot></div></thead>
  • <thead id="8rzwn"><xmp id="8rzwn">