(2/12)
003-01 / 20051205 / ea122_fmp.fm
All specifications are subject to change without notice.
FMP3W Type
SPECIFICATIONS AND STANDARDS
1 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range.
2 The output load variation is determined within the range set by the minimum output current and the maximum output current. Nominal values might
possibly not be satisfied when output is below the minimum output current.
3 Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage.
4 Output may fail to come on when operated in series.
Part No.
FMP05-R604
FMP12-R25
FMP24-R13
Rated output voltage and current1
5V 0.6A
12V 0.25A
24V 0.13A
Maximum output power
W
3
3.1
Input conditions
Input voltage Eac
V
85 to 132[Rating: 100 to 120]
Input frequency
Hz
47 to 440[Rating: 50 to 60](Single phase)
Input current
A
0.1max./0.08typ.[AC.85V]
Surge current
A
16max.[Input and output ratings, 25°C, cold start]
Leakage current
mA
0.5max.[Input and output ratings]
Efficiency
%
68typ.
70typ.
74typ.
Output characteristics
Output voltage Edc
V
5
12
24
Voltage variable range Edc
V
4.5 to 5.5
10.8 to 13.2
21.6 to 26.4
Maximum output current
A
0.6
0.25
0.13
Minimum output current2
A
0.06
0.02
0.01
Overcurrent threshold
A
0.7 to 1.2
0.3 to 0.5
0.15 to 0.3
Voltage
stability
Source effect
%
0.1typ.[Within the input voltage range]
Total effect ±3max.(±1typ.)
Load effect2
%
0.8typ.[10 to 100% load]
Temperature effect
%
1typ.[Ambient temperature: 0 to +50°C]
Drift(Time effect)
%
1max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Recovery
%/ms
±4max./1max.[50 to 100% sudden load change]
Ripple Ep-p
mV
50max.
80max.
100max.
Ripple noise Ep-p
mV
100max.
150max.
Start up time
ms
100max.
Hold up time
ms
20min.
Auxiliary functions
Indicator display
No
Overvoltage protection
Uses overvoltage prevention.3
Overcurrent protection
Rectangular type, automatic recovery.
Remote ON-OFF
No
Remote sensing
No
Output voltage external variable function
No
Standards
Safety standards
—
Noise terminal voltage
FCC class B meet.
Constructions
External dimensions
mm
19
×55×50[H×W×L](Except input and output terminals)
Weight
g
80max.
Mounting method
Can be attached to 1 side.
Case material
Nonflammable resin.
Input and output cables
No