■ RELIABILITY DATA
*This catalog contains the typical specication only due to the limitation of space. When you consider the purchase of our products, please check our specication.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
22. Resisitance to solvent
LA Type
Please avoid the ultrasonic cleaning of this product.
CAL45 Type
LHL□□□
FBA/FBR
No signicant abnormality in appearance
Impedance change : Within ±20%
FL05□ Type
FL06BT Type
【Test Method and Remarks】
FB : Solvent temperature : 20~25℃
Duration
: 30±5 sec.
Solvent type
: Acetone, trichloroethylene
Recovery
: 3hrs of recovery under the standard condition after the test.
23. Thermal shock
LA Type
△L/L : Within ±10% Q : 30min
CAL45 Type
△L/L : Within ±10%
LHL□□□
Appearance : No abnormality
Inductance change : Within ±10%
Q change : Within ±30% (LHLP:only △L/L)
FBA/FBR
Appearance : No abnormality
Impedance change : Within ±20%
FL05□ Type
Refer to individual specication
FL06BT Type
Appearance : No abnormality
Impedance change : Within ±20%
【Test Method and Remarks】
LA, CA
: Conditions for 1cycle
Step
Temperature (℃)
Duration (min.)
1
ー25+0
ー3
30±3
2
Room temperature
Within 3
3
+85+2
ー0
30±3
4
Room temperature
Within 3
Number of cycles : 5 cycles
Recovery
: At least 1hr of recovery under the standard condition after the removal from test chamber, followed by the measurement within 2hrs.
LHL□□□·FB : Accoding to JIS C0025
Conditions for 1 cycle
Step
Temperature (℃)
Duration (min.)
1
Minimum operating temperature+0
ー3
30±3
2
Room temperature
Within 3
3
Minimum operating temperature+2
ー0
30±3
4
Room temperature
Within 3
Number of cycles : 10 cycles〔LHL□□□〕
: 5 cycles (FBA, FBR)
Recovery
: 4 to 24hrs of recovery under the standard condition after the removal from the test chamber.〔LHL□□□〕
: 3hrs of recovery under the standard condition after the removal from the test chamber. (FBA, FBR)
FL
: Accoding to JIS C0025
Conditions for 1 cycle
Step
Temperature (℃)
Duration (min.)
1
ー25+0
ー3
30±3
2
Room temperature
Within 3
3
+85+2
ー0
30±3
4
Room temperature
Within 3
Number of cycles : 10 cycles
Recovery
: 1 to 2hrs of recovery under the standard condition after the removal from the test chamber.
24. Damp heat
LA Type
△L/L : Within ±10% Q : 30min
CAL45 Type
△L/L : Within ±10%
LHL□□□
FBA/FBR
Appearance:No abnormality
Impedance change:Within ±20%
FL05□ Type
FL06BT Type
【Test Method and Remarks】
LA, CA : Temperature : 40±2℃
Humidity
: 90~95%RH
Duration
: 1000 hrs
Recovery
: At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs.
FB : Temperature : 60±2℃
Humidity
: 90~95%RH
Duration
: 1000 hrs
Recovery
: 1 to 2hrs of recovery under the standard condition after the removal from the test chamber.