![](http://datasheet.mmic.net.cn/120000/FES200ZE-A_datasheet_3353052/FES200ZE-A_2.png)
FES DC-DC Series Data Sheet
Single-Output, 300 Watts
JAN 30, 2006 revised to JUN 15, 2006
Page 2 of 2
www.power-one.com
MODEL
INPUT VOLTAGE
MAXIMUM INPUT
OUTPUT
RATED OUTPUT
RIPPLE & NOISE
TYPICAL
(VOLTS)
RANGE (VOLTS)
CURRENT (AMPS)*
VOLTAGE (VOLTS)
CURRENT (AMPS)
pk-pk (mV)
EFFICIENCY**
FES132ZE-A
48
36 - 75
4.5
3.3
40
100
87%
FES200ZG-A
48
36 - 75
6.5
5.0
40
100
80%
FES200ZE-A
48
36 - 75
7.0
3.3
60
100
81%
FES300ZG-A
48
36 - 75
10.5
5.0
60
100
84%
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
Mechanical Drawing
Thermal Impedance
Natural Convection
5.4 °C/W
100 LFM
3.8 °C/W
200 LFM
2.5 °C/W
300 LFM
1.7 °C/W
400 LFM
1.6 °C/W
Tolerances
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated
for specific application.
Pin
Function
1-Vin
2
Case
3
Enable
4+Vin
5-Vout
6-Vout
7
-Sense
8
Trim
9
+Sense
10
+Vout
11
+Vout
Inches:
(Millimeters)
.XX ± 0.020
.X ± 0.5
.XXX ± .010
.XX ± 0.25
Pin:
± 0.002
± 0.05
(Dimensions as listed unless otherwise
specified.)
Model Selection
11
10
FES
9
8
7
6
5
4
3
2
1
BOTTOM VIEW
1.150"(29.2mm)
0.900"(22.9mm)
0.700"(17.8mm)
0.500"(12.7mm)
0.250"(6.4mm)
1.700"(43.2mm)
-.50"(-12.7mm)
-.300"(-7.6mm)
1.400"(35.6mm)
1.000"(25.4mm)
0.400"(10.2mm)
0
(0.6mm)
M3X.5 THROUGH 4PL
MOUNTINGINSERTS
(2.0mm)
(4.6mm)
0.18"
(12.7mm)
0.50"
0.025" REF.
DIA 0.080"
(116.8mm)
4.60"
(61.0mm)
2.40"
(1.0mm)
DIA 0.040"
6PL
5PL
0
(-5.1mm)
-0.20"
(106.7mm)
4.200"
Model numbers highlighted in yellow or shaded are not recommended for new designs.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.