Nov 7, 2006
Page 1 of 3
www.power-one.com
FE5A AC-DC Front End Data Sheet
Three-Phase Input, 5000 Watts
Features
Three-phase Ac input
High efficiency: 90% at full load
11.8 Watts/cubic inch power density
Power factor corrected
No minimum load required
Single-wire current sharing
Current limit and over-voltage protection
Full power up to 50o C
Compact size: 5” x 5” x 17”
LED supply status indicators
TUV, cTUVus & CB report
Model Number
FE5A-1D-0
FE5A-1E-0
FE5A-1F-0
FE5A-1G-0
FE5A-1H-0
FE5A-1J-0
Options O = M (Output power good – TTL high);
N (Power fail – TTL high); R (Reverse airflow)
Output Rating
12V/400A
15V/330A
24V/208A
28V/180A
36V/140A
48V/104A
Description
The ultra-compact FE5A Series Front-End Power Supply provides a single isolated output of up to 5000-Watts
with inputs ranging from 365 Vac to 528 Vac, 3 phase, and can handle frequencies from 47 Hz to 63 Hz. Designed
for high current applications requiring a compact size. The FE5A series operates either as a standalone unit or as
part of rack-mounted power systems. The supply provides true front-end capability to automatic test equipment,
telecom, data communications, and other distributed power designs.
Input Specifications
Input voltage range:
380 to 498 Vac, 480 Vac Nominal,
Three Phase, 47 to 63 Hz.
Power Factor:
>0.95 at full load and nominal line
Inrush Current:
40 A peak hot and cold start
Input Protection:
15A internal fuse per line is provided
Signals and Controls
LED Output Good Indicator:
Front panel green LED
indicates power supply is good; amber indicates fault.
LED AC Good Indicator:
Front panel green LED indicates
Ac input voltage is present and above minimum level.
Output Good Signal*:
TTL compatible signal, normally high.
Goes low when power supply is out of specified range.
Power Fail Signal*:
TTL compatible signal, normally high
(indicating Vin is present and above minimum level).
Enable*:
Normally TTL High, drive low to enable.
*All interface signals are TTL compatible
Output Specifications
Output Power:
5000 W maximum
Output Voltage & Current Ratings
: See chart shown above
Overshoot/Undershoot:
Less than 1% at turn-on or turn-off.
Less than 2% for 50% to 100% load step.
Start-Up Time:
Less than 3 seconds
Efficiency:
90% typical measured at full load, nominal input
Hold-up Time:
20 ms minimum at full load and low line
Overcurrent Protection:
Set to 105-130% of full rated load
with automatic recovery
Overtemperature Protection:
Automatic shutdown with auto
recovery.
Remote Sense:
Compensates for voltage drop of up to 0.5 V
to the load. Shorted sense lead protection.
Overvoltage Protection:
Set at 120%-130% of nominal;
reset by cycling input power.
Output Noise and Ripple:
PARD: 1% of output voltage
measured at 20 Mhz bandwidth.
Single Wire Current Share:
5% full load rating
Load Regulation:
0.5% with remote sense, 2% without
Line Regulation:
0.2% over entire operating range
Minimum Load: