![](http://datasheet.mmic.net.cn/110000/F-BN-AB-2100-ZE-200_datasheet_3352112/F-BN-AB-2100-ZE-200_1.png)
IEC Inlet Filters
F.BN series
General purpose modules
A comprehensive range of chassis mount IEC 60320 inlet power
entry modules housed in a compact and lightweight enclosure.
Offers a low cost form of protection from mains borne interference in
applications such as business, consumer, medical equipment,
VDU’s, computers, vending machines and many other general
purpose applications.
Current ratings from 1A to 10A
Component value combinations to suit requirements
Low cost design
Medical versions available
Approvals
Filter Range
Code
lR
LCx
Cy
IL
Circ
(A)
(mH)
(F)
(pF)
(mA)
Diag
F.BN.AB.2100.ZE.200
6
2x0.5
0.01
2x2700
2x0.25
A
F.BN.AB.2470.ZA.100
1
2x2.8
0.047
2x2200
2x0.2
A
F.BN.AB.2470.ZB.000
1
2x10
0.047
2x2500
2x0.23
A
F.BN.AB.2470.ZD.000
3
2x2.5
0.047
2x2500
2x0.23
A
F.BN.AB.2470.ZF.000
6
2x1
0.047
2x2500
2x0.23
A
F.BN.AB.2470.ZG.110
10
2x0.13
0.047
2x2200
2x0.2
A
F.BN.AB.2680.CZ.300
3
2x1
0.068
2x3300
2x0.3
B
F.BN.AB.2680.ZB.000
1
2x10
0.068
2x2500
2x0.23
A
F.BN.AB.2680.ZD.000
3
2x2.5
0.068
2x2500
2x0.23
A
F.BN.AB.2680.ZF.000
6
2x1
0.068
2x2500
2x0.23
A
F.BN.AB.3100.BZ.000
1
2x10
0.1
2x2500
2x0.23
B
F.BN.AB.3100.DZ.000
3
2x2.5
0.1
2x2500
2x0.23
B
F.BN.AB.3100.FZ.000
6
2x1
0.1
2x2500
2x0.23
B
F.BN.AB.3100.HZ.420
3
2x6
0.1
2x150
2x0.014 B
Electrical Specifications
Rated voltage (VR):
max 250V, 50/60Hz
Rated current (IR):
referred to room temperature = 40°C
Leakage current (IL): at 220V, 50Hz, max value
Voltage test (2S.):
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
Climatic category:
HPF (25/085/21):
Temperature range: -25°C to +85°C
Mechanical Specifications
Manufacture: metal case with built-in power line connector
according to IEC 60320 & EN 60320.
Connections: IEC 60320 - Standard plug (INPUT); faston
2x2.8 x 0.8mm or 6.3 x 0.8mm (OUTPUT);
ground terminal connected to case.
Dimensions (mm) and connections
Circuit diagram
Available Variants
A
B
F. BN. - -. - - - -. - -. - - 0
A = 2x2.8mm x 0.8 faston
B = 6.3mm x 0.8 faston
A = Standard Version
M = Medical Version
(without Y capacitors)
X Capacitance
2100 = 0.010uF
2470 = 0.047uF
2680 = 0.068uF
3100 = 0.1uF
Y Capacitance Current Leakage
0 = 2500pF
2x0.23 mA
1 = 2200pF
2x0.20 mA
2 = 2700pF
2x0.25 mA
3 = 3300pF
2x0.3 mA
4 = 150pF
2x0.014 mA
Resistor
0 = no resistor
1 = 1M
2 = 2.2M
IR , L & CCT.
CCT A CCT B
VALUES
ZA
AZ
1A, 2.8mH,
ZB
BZ
1A, 10mH,
ZC
CZ
3A, 1mH
ZD
DZ
3A, 2.5mH
ZE
EZ
6A, 0.5mH
ZF
FZ
6A, 1mH
ZG
GZ
10A, 0.13mH
ZH
HZ
3A, 6mH
22