2
I
Product Specification
Ratings
Operation temperature range
Voltage
Current
–
55
to
+
85
125 V AC
Signal contacts
Power supply contacts
1A
2A
I
Materials
G
Receptacle
Part
Measured at 250 V DC
Applied a voltage of 350 V AC for one minute.
5% concentration of salt water for 48 hours
Performed 3,000 cycles of insertion/withdrawal.
Frequency: 10 to 55 Hz (5 minutes per cycle)
Total amplitude: Test at 1.5 mm in 3 directions, 2 hours each
Acceleration: 490 m/s
2
, 11 ms duration
Test with a sine wave in 3 axes, both directions, 3 times
each
Conduct a test of 5 cycles of the following:
Temperature cycle
:
–
55
+
15 to
+
35
+
85
+
15 to
+
35
Time
:
–
30
+
10 to
+
15
+
30
10 to 15 minutes
Temperature of 40
±
2
and humidity of 90% to 95%
for 96 hours
Measured at 100 mA
Signal contacts: 40 m
max.
Power supply contacts: 16 m
max.
500 M
max.
No flashover or insulation breakdown
Contact resistance
Signal contacts: 60 m
max.
Power supply contacts: 24 m
max.
No damage, cracks, or loose parts
No momentary disconnections of 1
μ
s max.
Contact resistance
Signal contacts: 60 m
max.
Power supply contacts: 24 m
max.
No damage, cracks, or loose parts
Contact resistance
Signal contacts: 60 m
max.
Power supply contacts: 24 m
max.
Insulation resistance: 500 M
max.
No damage, cracks, or loose parts
No conspicuous corrosion
1.
Contact resistance
2.
Insulation resistance
3.
Withstand voltage
4.
Mechanical operation
5. Vibration
6. Shock
7.
Temperature cycle
8. Steady-state
8.
humidity resistance
9. Salt spray
Item
Standard
Condition
Gold plating
UL94U-0
Nickel plating
Solder plating
Copper alloy
LCP
Steel
Stainless steel
Contacts
Insulator
Body
Metal Fitting
Material
Finish
G
Plug
Selective gold plating
UL94U-0
Nickel plating
UL94U-0
Copper alloy
LCP
Steel
Polycarbonate
Contacts
Insulator
Body
Strain relief
Part
Material
Finish
G
Cover
UL94HB
-----
-----
UL94HB
-----
Black nickel plating
Polycarbonate
Stainless steel
Stainless steel
Polycarbonate
Brass
Steel
Cover
Shield
Lock
Push button
Clamp
Metal hold down
Part
Material
Finish