ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted. All voltages are relative to
their respective ground.
Table 6.
Parameter
Rating
VCC
0.5 V to +6 V
VIO
0.5 V to +6 V
Digital Input Voltage, TxD
0.5 V to VIO + 0.5 V
Digital Output Voltage, RxD
0.5 V to VIO + 0.5 V
CANH, CANL
36 V to +36 V
VREF
0.5 V to +6 V
RS
0.5 V to +6 V
Operating Temperature Range
40°C to +85°C
Storage Temperature Range
55°C to +150°C
ESD (Human Body Model)
3 kV
Lead Temperature
Soldering (10 sec)
300°C
Vapor Phase (60 sec)
215°C
Infrared (15 sec)
220°C
θJA Thermal Impedance
53°C/W
TJ Junction Temperature
130°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 7. Maximum Continuous Working Voltage1 Parameter
Max
Unit
Reference Standard
AC Voltage
Bipolar Waveform
424
V peak
50 year minimum
lifetime
Unipolar Waveform
Basic Insulation
1074
V peak
Maximum approved
working voltage per
IEC60950-1
Reinforced Insulation
537
V peak
Maximum approved
working voltage per
IEC60950-1
DC Voltage
Basic Insulation
1074
V peak
Maximum approved
working voltage per
IEC60950-1
Reinforced Insulation
537
V peak
Maximum approved
working voltage per
IEC60950-1
1
Refers to continuous voltage magnitude imposed across the isolation
ESD CAUTION