參數(shù)資料
型號: EVAL-ADE7755EB
廠商: Analog Devices, Inc.
英文描述: Energy Metering IC with Pulse Output
中文描述: 電能計量IC輸出脈沖
文件頁數(shù): 15/16頁
文件大?。?/td> 331K
代理商: EVAL-ADE7755EB
REV. 0
ADE7755
–15–
pulse rate, the frequency at this logic output is proportional to
the instantaneous real power. As is the case with F1 and F2, the
frequency is derived from the output of the low-pass filter after
multiplication. However, because the output frequency is high,
this real power information is accumulated over a much shorter
time. Hence, less averaging is carried out in the digital-to-
frequency conversion. With much less averaging of the real
power signal, the CF output is much more responsive to power
fluctuations (see Figure 2, signal processing block diagram).
Table IV. Maximum Output Frequency on CF
SCF
S1
S0
F
1–4
(Hz)
1.7
1.7
3.4
3.4
6.8
6.8
13.6
13.6
CF Max for AC Signals (Hz)
128
F1, F2 = 43.52
64
F1, F2 = 21.76
64
F1, F2 = 43.52
32
F1, F2 = 21.76
32
F1, F2 = 43.52
16
F1, F2 = 21.76
16
F1, F2 = 43.52
2048
F1, F2 = 5.57 kHz
1
0
1
0
1
0
1
0
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
SELECTING A FREQUENCY FOR AN ENERGY METER
APPLICATION
As shown in Table II, the user can select one of four frequencies.
This frequency selection determines the maximum frequency on
F1 and F2. These outputs are intended to be used to drive the
energy register (electromechanical or other). Since only four
different output frequencies can be selected, the available fre-
quency selection has been optimized for a meter constant of
100 imp/kWhr with a maximum current of between 10 A and
120 A. Table V shows the output frequency for several maxi-
mum currents (I
MAX
) with a line voltage of 220 V. In all cases
the meter constant is 100 imp/kWhr.
Table V. F1 and F2 Frequency at 100 imp/kWhr
I
MAX
12.5 A
25 A
40 A
60 A
80 A
120 A
F1 and F2 (Hz)
0.076
0.153
0.244
0.367
0.489
0.733
The F
1–4
frequencies allow complete coverage of this range of
output frequencies on F1 and F2. When designing an energy
meter, the nominal design voltage on Channel 2 (voltage) should
be set to half scale to allow for calibration of the meter constant.
The current channel should also be no more than half scale
when the meter sees maximum load. This will allow over current
signals and signals with high crest factors to be accommodated.
Table VI shows the output frequency on F1 and F2 when both
analog inputs are half scale. The frequencies listed in Table
VI align very well with those listed in Table V for maximum load.
Example 1
Thus if full-scale differential dc voltages of +470mV and –660 mV
are applied to V1 and V2 respectively (470 mV is the maximum
differential voltage that can be connected to Channel 1, and
660 mV is the maximum differential voltage that can be connected
to Channel 2), the expected output frequency is calculated as
follows:
Gain = 1,
G
0
= G
1
=
0
F
1–4
= 1.7 Hz,
S
0 =
S
1 = 0
V1 = +470 mV dc = 0.47 V (rms of dc = dc)
V2 = –660 mV dc = 0.66 V (rms of dc = |dc|)
V
REF
= 2.5 V (nominal reference value)
NOTE: If the on-chip reference is used, actual output frequencies
may vary from device to device due to reference tolerance of
±
8%.
8 06
0 47
.
.
Freq
=
2 5
.
=
0 66
.
1
1 7
.
0 68
.
2
Example 2
In this example, with ac voltages of
±
470 mV peak applied to
V1 and
±
660 mV peak applied to V2, the expected output
frequency is calculated as follows:
Gain = 1,
G
0 =
G
1 = 0
F
1–4
= 1.7 Hz,
S
0
=
S
1 = 0
V1 = rms of 470 mV peak ac = 0.47/
÷
2
volts
V2 = rms of 660 mV peak ac = 0.66/
÷
2
volts
V
REF
= 2.5 V (nominal reference value)
NOTE: If the on-chip reference is used, actual output frequencies
may vary from device to device due to reference tolerance of
±
8%.
2
As can be seen from these two example calculations, the maxi-
mum output frequency for ac inputs is always half of that for dc
input signals. Table III shows a complete listing of all maximum
output frequencies.
Freq
=
.
=
8 06
.
0 47
.
0 66
.
1
1 7
.
2
2 5
0 34
.
2
Table III. Maximum Output Frequency on F1 and F2
Max Frequency
for DC Inputs (Hz)
0.68
1.36
2.72
5.44
Max Frequency
for AC Inputs (Hz)
0.34
0.68
1.36
2.72
S1
0
0
1
1
S0
0
1
0
1
Frequency Output CF
The pulse output CF (Calibration Frequency) is intended for
use during calibration. The output pulse rate on CF can be up
to 2048 times the pulse rate on F1 and F2. The lower the F
1–4
frequency selected, the higher the CF scaling (except for the
high-frequency mode SCF = 0, S1 = S0 = 1). Table IV shows
how the two frequencies are related, depending on the states of
the logic inputs S0, S1, and SCF. Because of its relatively high
相關PDF資料
PDF描述
EVAL-ADE7756EB Active Energy Metering IC with Serial Interface
EVAL-ADE7757EB Energy Metering IC with Integrated Oscillator
EVAL-ADE7759E Active Energy Metering IC with di/dt Sensor Interface
EVAL-ADE7763EB Single-Phase Active and Apparent Energy Metering IC
EVAL-ADF4112EB1 CDMA Evaluation Board For PLL Frequency Synthesizer
相關代理商/技術參數(shù)
參數(shù)描述
EVAL-ADE7755EBZ 制造商:AD 制造商全稱:Analog Devices 功能描述:Energy Metering IC with Pulse Output
EVAL-ADE7755EBZ1 制造商:AD 制造商全稱:Analog Devices 功能描述:Energy Metering IC with Pulse Output
EVAL-ADE7755ZEB 功能描述:BOARD EVALUATION FOR AD7755 RoHS:是 類別:編程器,開發(fā)系統(tǒng) >> 評估演示板和套件 系列:- 標準包裝:1 系列:- 主要目的:電信,線路接口單元(LIU) 嵌入式:- 已用 IC / 零件:IDT82V2081 主要屬性:T1/J1/E1 LIU 次要屬性:- 已供物品:板,電源,線纜,CD 其它名稱:82EBV2081
EVAL-ADE7756EB 制造商:Analog Devices 功能描述:EVAL BD DOCUMENTATION ADE7756 ENERGY METERING IC - Bulk 制造商:Rochester Electronics LLC 功能描述:
EVAL-ADE7757AEBZ 制造商:Analog Devices 功能描述:EVALUATION BOARDS - Bulk