EiC Corp. A Subsidiary of EiC Enterprises, Ltd.
www.eiccorp.com
45738 Northport Loop West, Fremont, CA 94538
Phone: (510) 979-8999
Fax: (510) 979-8902
1
SS-000349-000 Rev G
PRELIMINARY DATA SHEET
ECG001
HIGH LINEARITY BROADBAND AMPLIFIER
DC - 6000 MHz
Description
The ECG001 is a high reliability, high linearity, low cost broadband amplifier, optimized for commercial communications.
The device is manufactured using in-house developed, advanced Indium Gallium Phosphide Heterojunction Bipolar Transistor
(InGaP HBT) technology and is designed for use as a 50 Ohm gain block. The amplifier features excellent VSWR, low noise
figure and highly linear performance. Typical OIP3 is +25dBm at 1000 MHz. The ECG001 operates from a single voltage
supply and requires only two DC-blocking capacitors, a bias resistor and an inductor for operation. The device is ideal for
wireless applications and is available in a low cost, surface-mountable plastic 85 mil Micro-X and SOT-89 packages. The
ECG001 is designed in the Darlington configuration with direct feedback. Its operation frequency at low end is limited only
by the DC blocking capacitor and the RF choke inductor (large values are required in both cases).
Electrical Specifications
Features
DC to 6000 MHz
20.0 dB Gain at 1000 MHz
12.5 dBm Output P1dB at 1000 MHz
25 dBm Output IP3 at 1000 MHz
3.7 dB Noise Figure at 2000 MHz
Test Conditions: Ic= 30mA Ta = 25
oC,
Applications
Broadband Gain Blocks
High Linearity Amplifiers
CAUTION!
SENSITIVE ELECTRONIC DEVICE
Packages Available
(-B) SOT-89
(-C) 85 Mil Micro-X
(-F) SOT-363
MIN.
TYP.
MAX.
F
Frequency
DC
6000
MHz
f = 1000MHz
20.0
f = 2000MHz
17.0
19.0
f = 3000MHz
17.0
18.0
f = 6000MHz
13.0
G
Gain(Large signal) Pin=-4.5dBm
f = 3000MHz
14.5
17.0
dB
f = 1000MHz
12.5
f = 2000MHz
12.5
f = 3000MHz
12.6
f = 1000MHz
25.0
f = 2000MHz
26.0
f = 3000MHz
26.0
RL
in
Input Return Loss, 50 Ohm
f = 2000MHz
14.0
dB
RL
out
Output Return Loss, 50 Ohm
f = 2000MHz
18.0
dB
NF
Noise Figure
f = 2000MHz
3.7
dB
Vde
Device Voltage
3.0
3.4
3.8
V
Note 1
Output Third Order Intercept
dBm
Note 1: OIP3 = Pout (by power meter, total 2-tone power) + (IM3(dB))/2) - 3dB
TEST CONDITION
LIMITS
UNIT
PARAMETER
SYMBOL
OIP3
G
dB
Gain (Small Signal)
P1dB
Output Power @ 1dB
Compression
dBm