4) VCC_ rises from 0 to 5V, 3V, or 1.8V with a controlled
參數(shù)資料
型號: DS8005-RJX+
廠商: Maxim Integrated Products
文件頁數(shù): 4/20頁
文件大?。?/td> 0K
描述: SMART CARD AFE DUAL 28TSSOP
標(biāo)準(zhǔn)包裝: 50
通道數(shù): 2
功率(瓦特): 700mW
電壓 - 電源,數(shù)字: 1.8V, 3V, 5V
封裝/外殼: *
供應(yīng)商設(shè)備封裝: *
包裝: *
DS8005
4) VCC_ rises from 0 to 5V, 3V, or 1.8V with a controlled
slope (t2 = t1 + 1.5
× T). T is 64 times the internal
oscillator period (approximately 25s).
5) I/O_ pin is enabled (t3 = t1 + 4T) (they were previ-
ously pulled low).
6) The CLK_ signal is applied to the C3 contact (t4).
7) RST_ is enabled (t5 = t1 + 7T).
To apply the clock to the card interface:
1) Set RSTIN high.
2) Set CMDVCC low.
3) Set RSTIN low between t3 and t5; CLK_ now starts.
4) RST_ stays low until t5, then RST becomes the copy
of RSTIN.
5) RSTIN has no further effect on CLK_ after t5.
If the applied clock is not needed, set CMDVCC low
with RSTIN low. In this case, CLK_ starts at t3 (minimum
200ns after the transition on I/O; see Figure 4); after t5,
RSTIN can be set high to obtain an answer to request
(ATR) from an inserted smart card. Do not perform acti-
vation with RSTIN held permanently high.
Active Mode
When the activation sequence is completed, the card
interface is in active mode. The host microcontroller
and the smart card exchange data on the I/O lines.
Deactivation Sequence
When a session is completed, the host microcontroller
sets the CMDVCC line high to execute an automatic
deactivation sequence and returns the card interface to
the inactive mode (Figure 5).
1) RST_ goes low (t10).
2) CLK_ is held low (t12 = t10 + 0.5
× T) where T is 64
times the period of the internal oscillator (approxi-
mately 25s).
3) I/O_ pin is pulled low (t13 = t10 + T).
4) VCC starts to fall (t14 = t10 + 1.5
× T).
5) When VCC_ reaches its inactive state, the deactiva-
tion sequence is complete (at tDE).
6) All card contacts become low impedance to GND;
I/OIN remains at VDD (pulled up through an 11k
Ω
resistor).
7) The internal oscillator returns to its lower frequency.
VCC Generator
Each VCC_ generator has a capacity to supply up to
80mA continuously at 5V, 65mA at 3V, and 30mA at
1.8V. An internal overload detector triggers at approxi-
mately 120mA. Current samples to the detector are fil-
tered. This allows spurious current pulses (with a
duration of a few s) up to 200mA to be drawn without
causing deactivation. The average current must stay
below the specified maximum current value. To main-
tain VCC voltage accuracy, a 100nF capacitor (with an
ESR < 100m
Ω) should be connected to CGND and
placed near the VCC_ pin, and a 100nF or 220nF
capacitor (220nF is the best choice) with the same ESR
should be connected to CGND and placed near the
smart card reader’s C1 contact.
Fault Detection
The following fault conditions are monitored:
Short-circuit or high current on VCC_
Removal of a card during a transaction
VDD dropping
Card voltage generator operating out of the specified
values (VDDA too low or current consumption too
high)
Overheating
There are two different cases (Figure 6):
CMDVCC High Outside a Card Session. Output
OFF_ is low if a card is not in the card reader and
high if a card is in the reader. The VDD supply is mon-
itored—a decrease in input voltage generates an
internal power-on reset pulse but does not affect the
OFF_ signal. Short-circuit and temperature detection
is disabled because the card is not powered up.
CMDVCC Low Within a Card Session. Output OFF_
goes low when a fault condition is detected, and an
emergency deactivation is performed automatically
(Figure 7). When the system controller resets CMD-
VCC to high, it may sense the OFF_ level again after
completing the deactivation sequence. This distin-
guishes between a card extraction and a hardware
problem (OFF_ goes high again if a card is present).
Depending on the connector’s card-present switch
(normally closed or normally open) and the mechani-
cal characteristics of the switch, bouncing can occur
on the PRES_ signals at card insertion or withdrawal.
The device has a debounce feature with an 8ms typical
duration (Figure 6). When a card is inserted, output
OFF_ goes high after the debounce time delay. When
the card is extracted, an automatic deactivation
sequence of the card is performed on the first true/false
transition on PRES_ and output OFF_ goes low.
Smart Card Interface
12
______________________________________________________________________________________
相關(guān)PDF資料
PDF描述
MAX908CSD+ IC COMPAR HS TRPL 14-SOIC
MAX961ESA+ IC COMP BEYOND-THE-RAILS 8-SOIC
VE-JNN-MY-F3 CONVERTER MOD DC/DC 18.5V 50W
VE-23P-CV-B1 CONVERTER MOD DC/DC 13.8V 150W
MCP6546-E/SN IC COMP 1.6V SNGL O-D 8SOIC
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
DS8005-RJX+ 功能描述:接口 - 專用 DUAL SMARTCARD AFE RoHS:否 制造商:Texas Instruments 產(chǎn)品類型:1080p60 Image Sensor Receiver 工作電源電壓:1.8 V 電源電流:89 mA 最大功率耗散: 最大工作溫度:+ 85 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:BGA-59
DS8005-RRX+ 功能描述:接口 - 專用 Dual Smart Card AFE RoHS:否 制造商:Texas Instruments 產(chǎn)品類型:1080p60 Image Sensor Receiver 工作電源電壓:1.8 V 電源電流:89 mA 最大功率耗散: 最大工作溫度:+ 85 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:BGA-59
DS8007 制造商:MAXIM 制造商全稱:Maxim Integrated Products 功能描述:Multiprotocol Dual Smart Card Interface 8kV (min) ESD Protection on Card Interfaces
DS8007_11 制造商:MAXIM 制造商全稱:Maxim Integrated Products 功能描述:Multiprotocol Dual Smart Card Interface 8kV (min) ESD Protection on Card Interfaces
DS8007A 制造商:MAXIM 制造商全稱:Maxim Integrated Products 功能描述:Multiprotocol Dual Smart Card Interface