![](http://datasheet.mmic.net.cn/Vishay-Siliconix/DG538ADJ-E3_datasheet_96888/DG538ADJ-E3_5.png)
DG534A/538A
Vishay Siliconix
Document Number: 70069
S-05734—Rev. G, 29-Jan-02
www.vishay.com
5
SPECIFICATIONSa
Test Conditions
Unless Otherwise Specified
A Suffix
–55 to 125
_C
D Suffix
–40 to 85
_C
Parameter
Symbol
V+ = 15 V, V– = –3 V, VL = 5 V
WR = 0.8 V, RS, EN= 2 V
Tempb
Typc
Mind
Maxd
Mind
Maxd
Unit
Dynamic Characteristics (Cont’d)
RL = 75 W, f = 5 MHz
PLCC
Room
–75
Chip Disabled Crosstalkf
XTALK(CD)
EN = 0.8 V
See Figure 8
DIP
Room
–65
RIN = 10 W
RL = 10 kW
PLCC
Room
–97
Adjacent Input Crosstalkf
XTALK(AI)
RL = 10 kW
f = 5 MHz
SeeFigure 9
DIP
Room
–87
Adjacent Input Crosstalk
XTALK(AI)
RIN = 75 W, RL = 75 W
PLCC
Room
–80
f = 5 MHz
See Figure 7
DIP
Room
–70
RIN = 10 W
RL = 10 kW
PLCC
Room
–77
dB
All Hostile Crosstalk
XTALK(AH)
RL = 10 kW
f = 5 MHz
See Figure 7
DIP
Room
–72
All Hostile Crosstalk
XTALK(AH)
RIN = 75 W, RL = 75 W
PLCC
Room
–77
f = 5 MHz
See Figure 7
DIP
Room
–72
RIN = 10 W, RL = 10 kW
f = 5 MHz, See Figure 10
Room
–84
Differential Crosstalk
XTALK(DIFF)
RIN = RL = 75 W
f = 5 MHz, See Figure 10
Room
–84
Bandwidth
BW
RL = 50 W, See Figure 6
Room
500
MHz
Power Supplies
Positive Supply Current
I+
Any One Channel Selected with Ad-
Room
Full
0.6
2
5
2
5
Negative Supply Current
I–
Any One Channel Selected with Ad-
dress Inputs at GND or 5 V
Room
Full
0.6
–1.8
–2
–1.8
–2
mA
V+ to V–
Full
10
21
10
21
Functional Check of
Maximum Operating
V– to GND
Functional Test Only
Full
–5.5
0
–5.5
0
V
Supply Voltage Range
V+ to GND
Full
10
21
10
21
Logic Supply Current
IL
Full
150
500
mA
Timing
Reset to Write
tRW
Room
Full
–22
50
WR, RS
Minimum Pulse Width
tMPW
Room
Full
60
200
A0, A1, EN
Data Valid to Strobe
tDW
Room
Full
20
100
A0, A1, EN
Data Valid after Strobe
tWD
See Figure 1
Room
Full
–20
50
ns
Address Bus Tri-Statee
tAZ
Room
25
Address Bus Output
tAO
Room
95
Address Bus Input
tAI
Room
110
Notes:
a.
Refer to PROCESS OPTION FLOWCHART.
b.
Room = 25
_C, Full = as determined by the operating temperature suffix.
c.
Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d.
The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e.
Defined by system bus requirements.
f.
Each individual pin shown as GND must be grounded.
g.