DG300B/301B/302B/303B
Vishay Siliconix
www.vishay.com
4
Document Number: 71402
S-02968
—
Rev. A, 22-Jan-01
Test Conditions Unless Specified
Limits
–
40 to 85 C
Typ
c
Parameter
Symbol
V+ = 15 V, V
–
=
–
15 V
V
IN
= 0.8 V or V
IN
= 4 V
f
Temp
b
Min
d
Max
d
Unit
Analog Switch
Analog Signal Range
e
V
ANALOG
Full
–
15
15
V
Drain-Source On-Resistance
r
DS(on)
V
D
=
10 V, I
S
=
–
10 mA
Room
Full
Room
Hot
Room
Hot
Room
Hot
30
50
75
5
100
5
100
5
100
Source Off Leakage Current
I
S(off)
–
5
–
100
–
5
–
100
–
5
–
100
0.1
Drain Off Leakage Current
I
D(off)
V
S
=
14 V, V
D
=
14 V
0.1
nA
Drain On Leakage Current
I
D(on)
V
D
= V
S
=
14 V
0.1
Digital Control
Input Current with
Input Voltage High
V
IN
= 5 V
Room
Full
–
1
–
0.001
I
INH
V
IN
= 15 V
Room
Full
Room
Full
0.001
1
A
Input Current with
Input Voltage Low
I
INL
V
IN
= 0 V
–
1
–
0.001
Dynamic Characteristics
Turn-On Time
t
ON
t
OFF
Room
150
Turn-Off Time
See Figure NO TAG
Room
130
Break-Before-Make Time
t
OPEN
DG301B/303B Only
Figure NO TAG
C
L
= 1 nF, R
= 0
V
gen
= 0 V, Figure NO TAG
Room
50
ns
Charge Injection
Q
Room
8
pC
Source-Off Capacitance
Drain-Off Capacitance
Channel-On Capacitance
C
S(off)
C
D(off)
C
D(on)
Room
Room
Room
Room
Room
Room
Room
14
14
40
6
7
62
74
V
, V
= 0 V, f = 1 MHz
S
D
pF
V
IN
= 0 V
V
IN
= 15 V
Input Capacitance
C
in
f = 1 MHz
Off-Isolation
Crosstalk (Channel-to-Channel)
OIRR
X
TALK
V
= 0 V, R
= 1 k
V
S
= 1 V
rms
, f = 500 kHz
dB
Power Supplies
Positive Supply Current
I+
V
IN
= 4 V (One Input)
All Others = 0 V
Room
Full
0.23
1
mA
Negative Supply Current
I
–
Room
Full
Room
Full
Room
Full
–
100
–
0.001
Positive Supply Current
I+
0.001
100
A
Negative Supply Current
I
–
V
IN
= 0.8 V (All Inputs)
–
100
–
0.001
Notes:
a.
b.
c.
d.
e.
f.
Refer to PROCESS OPTION FLOWCHART.
Room = 25 C, Full = as determined by the operating temperature suffix.
Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
Guaranteed by design, not subject to production test.
V
IN
= input voltage to perform proper function.