DG189/190/191
Vishay Siliconix
www.vishay.com
4
Document Number: 70034
S-51140—Rev. D, 20-Jun-05
SPECIFICATIONS
a FOR DG190
Test Conditions
Unless Specified
A Suffix
55 to 125_C
B Suffix
25 to 85_C
Parameter
Symbol
V+ = 15 V, V = 15 V, VL = 5 V
VR = 0 V, VIN = 0.8 V or 2 Vf Unit
Analog Switch
VANALOG
Full
7.5
15
7.5
15
V
Drain-Source
On-Resistance
rDS(on)
IS = 10 mA, VD = 7.5 V
Room
Full
18
30
60
50
75
W
Source Off
IS( ff)
VS = "10 V, VD = #10 V
V+ = 10 V, V = 20 V
Room
Hot
0.06
1
100
5
100
Source Off
Leakage Current
IS(off)
VS = "7.5 V, VD = #7.5 V
Room
Hot
0.1
1
100
5
100
Drain Off
ID( ff)
VS = "10 V, VD = #10 V
V+ = 10 V, V = 20 V
Room
Hot
0.05
1
100
5
100
nA
Drain Off
Leakage Current
ID(off)
VS = "7.5 V, VD = #7.5 V
Room
Hot
0.06
1
100
5
100
Channel On
Leakage Current
ID(on)
VD = VS = "7.5 V
Room
Hot
0.02
2
200
10
200
Digital Input
Input Current with
Input Voltage High
IINH
VIN = 5 V
Room
Hot
<0.01
10
20
10
20
mA
Input Current with
Input Voltage Low
IINL
VIN = 0 V
Full
30
250
mA
Dynamic Characteristics
Turn-On Time
ton
See Switching Time Test Circuit
Room
85
150
180
ns
Turn-Off Time
toff
See Switching Time Test Circuit
Room
95
130
150
ns
Source-Off Capacitance
CS(off)
VS = 5 V, ID = 0
Room
9
Drain-Off Capacitance
CD(off)
f = 1 MHz
VD = 5 V, IS = 0
Room
6
pF
Channel-On Capacitance
CD(on)
VD = VS = 0 V
Room
14
Off Isolation
OIRR
f = 1 MHz, RL = 75 W
Room
>50
dB
Power Supplies
Positive Supply Current
I+
Room
0.6
1.5
Negative Supply Current
I
VIN = 0 V or 5 V
Room
2.7
5
mA
Logic Supply Current
IL
VIN = 0 V, or 5 V
Room
3.1
4.5
mA
Reference Supply Current
IR
Room
1
2
Notes:
a.
Refer to PROCESS OPTION FLOWCHART.
b.
Room = 25_C, Full = as determined by the operating temperature suffix.
c.
Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d.
The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e.
Guaranteed by design, not subject to production test.
f.
VIN = input voltage to perform proper function.