D-Sub
MILITARY QUALITY,
REMOVABLE CONTACT, HIGH DENSITY
SUBMINIATURE-D CONNECTORS
FOR MILITARY AND SEVERE INDUSTRIAL ENVIRONMENTAL APPLICATIONS
Positronic Industries
connectpositronic.com
53
DIMENSIONS ARE IN INCHES [MILLIMETERS].
ALL DIMENSIONS ARE SUBJECT TO CHANGE.
DD
SERIES
MILITARY QUALITY,
REMOVABLE CONTACT, HIGH DENSITY
SUBMINIATURE-D CONNECTORS
FOR MILITARY AND SEVERE INDUSTRIAL ENVIRONMENTAL APPLICATIONS
CRIMPING INFORMATION FOR DD AND ODD SERIES CRIMP CONTACTS
USE INDICATED POSITRONIC TOOLS FOR BEST RESULTS
Step 1: Strip wire to indicated length.
Step 2: Crimp wire to contact.
For Hand Crimp Tool: - Place contact into crimping tool.
- Insert wire into contact.
- Center contact by slowly closing the
crimping tool until the crimp indenters
make contact with the crimp barrel.
- Complete the cycle of the crimping tool in
one smooth motion.
- Remove the crimped contact.
Take Care Not To: - Damage or remove strands.
- Untwist or overtwist strands.
- Leave insulation particles on strands.
- Damage insulation.
For Automatic Pneumatic Crimp Tool:
- Insert the wire into the contact, positioned in the
crimp tool by the plastic carrier.
- Depress the activating device of the crimping
tool to start the crimping cycle.
- Remove the crimped contact.
0.150
[3.81]
Insulation
Stranded wire
Strands damaged
or removed by
stripping tool.
Insulation cut
incorrectly.
Strands overtwisted.
Particles of
insulation on the
stripped part of
the wire.
Wire insulation
damaged.
Strands untwisted.
Examples of Stripping Faults
Correctly Stripped Wire
±0.010 [0.25]