5
220 pF
RF Out
22 nH
Bias In
V
REF
100 pF
1.8 k
1.8 k
100 pF
100 k
100 k
V
DET
RF In
SK39374
Rev 2
DD2
DD0*-92
Evaluation Board Layout
0.079 (2.00 mm)
± 0.008 (0.20 mm)
0.049 (1.25 mm)
± 0.004 (0.10 mm)
0.008 (0.20 mm)
± 0.004 (0.10 mm)
0.087 (2.20 mm)
± 0.008 (0.20 mm)
0.035 (0.90 mm)
± 0.004 (0.10 mm)
0.002 (0.005 mm)
± 0.002 (0.005 mm)
0.037 (0.95 mm)
± 0.006 (0.15 mm)
0.010 (0.25 mm)
± 0.006 (0.15 mm)
0.0055
(0.14 mm)
± 0.0015
(0.04 mm)
0.0256 (0.65 mm)
BSC
0.009 (0.23 mm)
Ref.
Pin 1 Indicator
SC-88 (6 Lead SC-70)
RF In
RF Out
6
5
4
3
2
1
100 pF
100 k
1.0 V
1.8 k
1.8 k
22 nH
1 V
Bias
100 pF
100 k
150 pF
+
–
Differential
Amplifier
Detect Out
V
DET
V
REF
Test Circuit
Characteristic Value
Incident power (CW)
@ SWR = 2.0 max.
4 W @ < 1 GHz
2 W @ 1–2.5 GHz
DC bias current
10 mA
Operating temperature
-40 to +85 °C
Storage temperature
-65 to +150 °C
ESD
+200 V
Absolute Maximum Ratings
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
CAUTION:
Although this device is designed to be as robust as
possible, Electrostatic Discharge (ESD) can damage
this device.This device must be protected at all times
from ESD. Static charges may easily produce poten-
tials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.