DCP0105
GENERAL (Cont)
Efficiency
DCP010505
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
T
A
= +85
°
C
T
A
= +55
°
C
T
A
= +25
°
C
71
40
66
47
72
38
72
36
73
40
75
38
%
%
%
%
%
%
%
%
%
%
%
%
hrs
hrs
hrs
DCP010505D
DCP010512
DCP010512D
DCP010515
DCP010515D
MTTF
(3)
158,000
3,050,000
108,000,000
Weight
14-Pin PDIP
1.08
g
THERMAL SHUTDOWN
Internal Controller IC Temperature
Shutdown Current
115
140
°
C
mA
3
TEMPERATURE RANGE
Operating
–40
+100
°
C
NOTES: (1) 100% load current = 1W/V
NOM
typical. (2) Rated working voltage = 130Vrms (IEC950 Convention). (3) Life test data.
SPECIFICATIONS
(CONT)
At T
A
= +25
°
C, V
S
= +5V, unless otherwise specified.
DCP0105 SERIES
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
EMC SPECIFICATIONS
Specifications and Related Documents
The DCP010505 was tested to and complied with the limits of the following EMC specifications:
prEN55022 (1992)
Conducted RF emission, telecomm lines.
EN55022 (1995)
Limits and methods of measurement of radio interference characteristics of information technology equipment.
ENV50140 (1993)
Electromagnetic compatibility. Basic immunity standard. Radiated RF immunity.
ENV50141 (1993)
Electromagnetic compatibility. Basic immunity standard. Conducted RF immunity.
EN61000-4-2 (1995)
Electromagnetic compatibility, Part 4. Testing and measurement techniques, Section 2. Electrostatic
discharge.
EN61000-4-4 (1995)
Electromagnetic compatibility, Part 4. Testing and measurement techniques, Section 4. Electrical fast
transient bursts.
EN61000-4-8 (1994)
Electromagnetic compatibility, Part 4. Testing and measurement techniques, Section 8. Power frequency
magnetic field immunity.
List of Tests
The following is a list of tests which were required for compliance with the above specifications:
Conducted Emission Test
150kHz to 30MHz, power and output lines, Class B limits applying. DC/DC loads of
0%, 8%, and 120% applying.
Radiated Emission Test
30MHz to 1000MHz, Class B limits applying. DC/DC loads of 0%, 8%, and 120%
applying.
Radiated Immunity Test, Electric Field
80MHz to 1000MHz, 10V/m, 1kHz 80% AM.
Radiated Immunity Test, Electric Field
900MHz, 10V/m, 200Hz 100% PM.
Electrostatic Discharge Test
4kV, HCP/VCP indirect discharge only.
Electrical Fast Transient Tests
2kV power lines, 2kV signal lines.
Conducted RF Immunity Tests
150kHz to 80MHz, power and output lines, 10Vrms, 1kHz 80% AM.
Radiated Immunity Test, Magnetic Field
50Hz, 30A/m