CY27C256
3
Operating Range
Range
Ambient
Temperature
V
CC
Commercial
0
°
C to +70
°
C 
-40
°
C to +85
°
C 
-55
°
C to +125
°
C 
5V 
±
10%
Industrial
[2]
5V 
±
10%
Military
[3]
5V 
±
10%
Electrical Characteristics 
Over the Operating Range
[4]
27C256-45, 55, 70, 90, 
120, 150, 200
Min.
2.4
Parameter
V
OH
V
OL
V
IH
Description
Test Conditions
Max.
Unit
V
V
V
Output HIGH Voltage
Output LOW Voltage
Input HIGH Level
V
CC
 = Min., I
OH
 = –4.0 mA
V
CC
 = Min., I
OL
 = 16.0 mA
[5]
Guaranteed Input Logical HIGH Voltage for All 
Inputs
Guaranteed Input Logical LOW Voltage for All 
Inputs
GND < V
IN
 < V
CC
GND < V
OUT
 < V
CC
, 
Output Disabled
0.4
V
CC
2.0
V
IL
Input LOW Level
–0.3
0.8
V
I
IX
I
OZ
Input Current
Output Leakage Current
–10
–10
–40
–20
+10
+10
+40
–90
45
55
μ
A
μ
A
Commercial
Military
I
OS
I
CC
Output Short Circuit Current
[6]
Power Supply Current
V
CC
 = Max., V
OUT
 = GND
V
CC
 = Max., V
IN
 =V
IH
,
I
OUT
 = 0 mA, CE=V
IL
,
OE = V
IH
V
CC
 = Max., CE = V
IH
mA
mA
Commercial
Military
I
SB
Standby Supply Current
Commercial
Military
15
20
13
50
mA
V
PP
I
PP
V
IHP
Programming Supply Voltage
Programming Supply Current
Input HIGH Programming 
Voltage
Input LOW Programming 
Voltage
12
V
mA
V
3.0
V
ILP
0.4
V
Capacitance
[7]
Parameter
Description
Test Conditions
Max.
Unit
C
IN
Input Capacitance
T
A
 = 25
°
C, f = 1 MHz,
V
CC
 = 5.0V
10
pF
C
OUT
Output Capacitance
10
pF
Notes:
2.
3.
4.
5.
6.
7.
Contact a Cypress representative for information on industrial temperature range specifications.
T
 is the “instant on” case temperature.
See the last page of this specification for Group A subgroup testing information.
I
=12.0 mA for military devices.
For test purposes, not more than one output at a time should be shorted. Short circuit test duration should not exceed 30 seconds.
See Introduction to CMOS PROMs in this Data Book for general information on testing.