參數(shù)資料
型號(hào): CT2578-02-IN-F84
廠商: Aeroflex Inc.
英文描述: CT2578 / CT2581 SIMPLE REMOTE TERMINAL FOR MIL-STD-1553 / 1760 & McAir
中文描述: CT2578 / CT2581簡(jiǎn)單的遠(yuǎn)程終端的MIL - STD -一千七百六十零分之一千五百五十三
文件頁數(shù): 9/22頁
文件大?。?/td> 297K
代理商: CT2578-02-IN-F84
RX
CMD
DATA DATA
DATA
*
STATUS
RX
CMD
DATA
*
STATUS
STATUS
TX
CMD
*
9
SCDCT2578 REV B 3/11/98
Error Conditions
Action taken by device
1. Invalid command.
No response.
Command ignored.
2. Command followed by
another word.
No status response.
Set message error.
Sequence terminated.
3. Broadcast address.
No status response.
Set message error.
Set broadcast.
Sequence terminated.
4. Too few NSSTRB from
subsystem.
Message truncated.
5.Too many NSSTRB from
subsystem.
Bit 1 of BIT register set.
Too many data words will
not be transmitted.
Note: Sequence terminated - termination will take place before
signal NCMDSTRB becomes active, therefore no transfers to /
from subsystem will occur.
BC TO RT TRANSFER
If a valid command is received to receive up to 32 data words and
the second word is another command word then an RT to RT
transfer has been set up (see RT to RT transfer).
All valid data words received are stored in the data buffer memory
until message validation is complete after which the device will
respond with Status.
f the command was a broadcast the status transmission will be
suppressed and the broadcast bit in the status register set.
Data words are also available on T0-T15 as they are received
indicated by signal NDATA.
Only after the message has been completely validated will the data
be transferred to the subsystem in a single burst at 500 nS per
word. This ensures that only complete validated messages are
transferred to the subsystem.
When a complete validated message is stored in the data buffer
memory the signal NCMDSTRB goes low for 8.5 uS synchronized
to the 1 MHZ clock indicating that a completely validated message
has been received. The receive Command word appears on T0-T15
at this time.
If the Busy bit of the Status is set the sequence will terminate after
NCMDSTRB.
The end of the NCMDSTRB will initiate the DMA cycle to transfer
the data words from the data buffer memory to the subsystem. The
first word received is enabled onto T0-T15 and the signal
NDATAST is pulsed low. This sequence is repeated for each data
word that was received.
Error Conditions
Action taken by device
1. Invalid command.
No response.
Command ignored.
2. Invalid data word.
No status response.
Set message error.
Sequence terminated.
3. Non contiguous data.
No status response.
Set message error.
Sequence terminated.
4. Too few data words.
No status response.
Set message error.
Sequence terminated.
5. Too many data words.
No status response.
Set message error.
Set broadcast.
Sequence terminated.
Note: Sequence terminated - termination will take place before
signal NCMDSTRB becomes active, therefore no transfers to /
from subsystem will occur.
RT TO RT TRANSFER
o initiate an RT to RT transfer the Bus Controller will send a
receive command to RTA followed contiguously by a transmit
command to RTB.
TB will respond with status and contiguous data (see RT to BC
transfer).
TA (the receiving terminal) will receive the status and data
transmitted by RTB and store the received data in the data buffer
memory until the entire RT to RT transfer has been validated, after
which it will respond with its own status provided it was not a
broadcast command, in which case the status transmission will be
suppressed and the broadcast bit set. It will then transfer the data
to the subsystem (see BC to RT transfer).
The error detection for the transmitting terminal will be the same
as for RT to BC transfer. The error detection for the receiving
terminal is as follows:-
相關(guān)PDF資料
PDF描述
CT2578-02-IN-P119 CT2578 / CT2581 SIMPLE REMOTE TERMINAL FOR MIL-STD-1553 / 1760 & McAir
CT2578-02-XT-F84 CT2578 / CT2581 SIMPLE REMOTE TERMINAL FOR MIL-STD-1553 / 1760 & McAir
CT2578-02-XT-P119 CT2578 / CT2581 SIMPLE REMOTE TERMINAL FOR MIL-STD-1553 / 1760 & McAir
CT2578-12-CG-F84 CT2578 / CT2581 SIMPLE REMOTE TERMINAL FOR MIL-STD-1553 / 1760 & McAir
CT2578-12-CG-P119 CT2578 / CT2581 SIMPLE REMOTE TERMINAL FOR MIL-STD-1553 / 1760 & McAir
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
CT2578-02-IN-P119 制造商:AEROFLEX 制造商全稱:AEROFLEX 功能描述:CT2578 / CT2581 SIMPLE REMOTE TERMINAL FOR MIL-STD-1553 / 1760 & McAir
CT2578-02-QM-F84 制造商:AEROFLEX 制造商全稱:AEROFLEX 功能描述:CT2578 / CT2581 SIMPLE REMOTE TERMINAL FOR MIL-STD-1553 / 1760 & McAir
CT2578-02-QM-P119 制造商:AEROFLEX 制造商全稱:AEROFLEX 功能描述:CT2578 / CT2581 SIMPLE REMOTE TERMINAL FOR MIL-STD-1553 / 1760 & McAir
CT2578-02-XT-F84 制造商:AEROFLEX 制造商全稱:AEROFLEX 功能描述:CT2578 / CT2581 SIMPLE REMOTE TERMINAL FOR MIL-STD-1553 / 1760 & McAir
CT2578-02-XT-P119 制造商:AEROFLEX 制造商全稱:AEROFLEX 功能描述:CT2578 / CT2581 SIMPLE REMOTE TERMINAL FOR MIL-STD-1553 / 1760 & McAir