11
82C54
MODE DEFINITIONS
The following are defined for use in describing the operation
of the 82C54.
CLK PULSE -
A rising edge, then a falling edge, in that
order, of a Counter’s CLK input.
TRIGGER -
A rising edge of a Counter’s Gate input.
COUNTER LOADING -
The transfer of a count from the CR
to the CE (See “Functional Description”)
MODE 0: INTERRUPT ON TERMINAL COUNT
Mode 0 is typically used for event counting. After the Control
Word is written, OUT is initially low, and will remain low until
the Counter reaches zero. OUT then goes high and remains
high until a new count or a new Mode 0 Control Word is
written to the Counter.
GATE = 1 enables counting; GATE = 0 disables counting.
GATE has no effect on OUT.
After the Control Word and initial count are written to a
Counter, the initial count will be loaded on the next CLK
pulse. This CLK pulse does not decrement the count, so for
an initial count of N, OUT does not go high until N + 1 CLK
pulses after the initial count is written.
If a new count is written to the Counter it will be loaded on
the next CLK pulse and counting will continue from the new
count. If a two-byte count is written, the following happens:
1. Writing the first byte disables counting. Out is set low
immediately (no clock pulse required).
2. Writing the second byte allows the new count to be
loaded on the next CLK pulse.
This allows the counting sequence to be synchronized by
software. Again OUT does not go high until N + 1 CLK
pulses after the new count of N is written.
COMMANDS
DESCRIPTION
RESULT
D7
D6
D5
D4
D3
D2
D1
D0
1
0
1
0
Read-Back Count and Status of Counter 0
Count and Status Latched for Counter 0
1
0
1
0
Read-Back Status of Counter 1
Status Latched for Counter 1
1
0
1
0
Read-Back Status of Counters 2, 1
Status Latched for Counter 2,
But Not Counter 1
1
0
1
0
Read-Back Count of Counter 2
Count Latched for Counter 2
1
0
1
0
Read-Back Count and Status of Counter 1
Count Latched for Counter 1,
But Not Status
1
0
1
0
Read-Back Status of Counter 1
Command Ignored, Status Already
Latched for Counter 1
FIGURE 7. READ-BACK COMMAND EXAMPLE
CS
RD
WR
A1
A0
01000
Write into Counter 0
01001
Write into Counter 1
01010
Write into Counter 2
01011
Write Control Word
00100
Read from Counter 0
00101
Read from Counter 1
00110
Read from Counter 2
00111
No-Operation (Three-State)
1
XXXX
No-Operation (Three-State)
0
1
X
No-Operation (Three-State)
FIGURE 8. READ/WRITE OPERATIONS SUMMARY
相關(guān)PDF資料
PDF描述
V300A5M300BG2 CONVERTER MOD DC/DC 5V 300W
MS17344R22C22SX CONN PLUG 4POS STRAIGHT W/SCKT
PI3VT34X245BE IC XLATR BUS SWITCH LV 80-BQSOP
D38999/26MJ90SN CONN PLUG 46POS STRAIGHT W/SCKT
PI5C3861QE IC 10BIT 2PORT BUS SWITCH 24QSOP
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
CS82C54-1096 功能描述:計時器和支持產(chǎn)品 PERIPH PRG-CNTR 5V 10MHZ 28PLCC COMEL RoHS:否 制造商:Micrel 類型:Standard 封裝 / 箱體:SOT-23 內(nèi)部定時器數(shù)量:1 電源電壓-最大:18 V 電源電壓-最小:2.7 V 最大功率耗散: 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 封裝:Reel
CS82C54-10Z 功能描述:計時器和支持產(chǎn)品 PERIPH PRG-CNTR 5V 10MHZ 28PLCC COM RoHS:否 制造商:Micrel 類型:Standard 封裝 / 箱體:SOT-23 內(nèi)部定時器數(shù)量:1 電源電壓-最大:18 V 電源電壓-最小:2.7 V 最大功率耗散: 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 封裝:Reel
CS82C54-10Z 制造商:Intersil Corporation 功能描述:Package/Case:28-PLCC
CS82C54-10Z96 功能描述:計時器和支持產(chǎn)品 PERIPH PRG-CNTR 5V 10MHZ 28PLCC COMEL RoHS:否 制造商:Micrel 類型:Standard 封裝 / 箱體:SOT-23 內(nèi)部定時器數(shù)量:1 電源電壓-最大:18 V 電源電壓-最小:2.7 V 最大功率耗散: 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 封裝:Reel
CS82C54-12 功能描述:計時器和支持產(chǎn)品 PERIPH PRG-CNTR 5V 12 5MHZ 28PLCC COM RoHS:否 制造商:Micrel 類型:Standard 封裝 / 箱體:SOT-23 內(nèi)部定時器數(shù)量:1 電源電壓-最大:18 V 電源電壓-最小:2.7 V 最大功率耗散: 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 封裝:Reel