CP
RATING
1. Coil data
Note: Other pick-up voltage types are also available. Please contact us for details.
2. Specications
1) Standard CP relay
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*3. Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you conrm operation under actual conditions.
2) For wiper load
Anything outside of that given below complies with standard CP relays.
Note: *1. Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you conrm operation under actual conditions.
Nominal coil
voltage
Pick-up voltage
(at 20
°C 68°F)
Drop-out voltage
(at 20
°C 68°F)
Nominal operating
current
[
±10%] (at 20°C 68°F)
Coil resistance
[
±10%] (at 20°C 68°F)
Nominal operating
power
(at 20
°C 68°F)
Usable voltage range
(at 85
°C 185°F)
12V DC
Max. 7.2V DC
(Initial)
Min. 1.0V DC
(Initial)
53.3 mA
225
640 mW
10 to 16V DC
Characteristics
Item
Specications
Contact
Arrangement
1 Form A
1 Form C
Initial contact resistance (Initial)
N.O.: Typ6m
, N.C.: Typ8m (By voltage drop 6V DC 1A)
Contact material
Ag alloy (Cadmium free)
Rating
Nominal switching capacity (resistive load)
20A 14V DC
N.O.: 20A 14V DC, N.C.: 10A 14V DC
Max. carrying current (12V DC initial)*3
N.O.: 40A for 2 minutes, 30A for 1 hour (at 20
°C 68°F)
35A for 2 minutes, 25A for 1 hour (at 85
°C 185°F)
Nominal operating power
640 mW
Min. switching capacity (resistive load)*1
1A 12V DC
Electrical
characteristics
Insulation resistance (Initial)
Min. 100 M
(at 500V DC)
Breakdown voltage
(Initial)
Between open contacts
500 Vrms for 1 min. (Detection current: 10mA)
Between contacts and coil
500 Vrms for 1 min. (Detection current: 10mA)
Operate time (at nominal voltage)
Max. 10ms (at 20
°C 68°F, excluding contact bounce time) (Initial)
Release time (at nominal voltage)
Max. 10ms (at 20
°C 68°F, excluding contact bounce time) (Initial)
Mechanical
characteristics
Shock resistance
Functional
Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection: 10
s)
Destructive
Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms)
Vibration resistance
Functional
10 Hz to 100 Hz, Min. 44.1 m/s2 {4.5G} (Detection time: 10
s)
Destructive
10 Hz to 500 Hz, Min. 44.1 m/s2 {4.5G}
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Expected life
Mechanical
Min. 107 (at 120 cpm)
Electrical
*Motor load does not apply to wiper load
applications.
<Resistive load>
Min. 105 (At nominal switching capacity, operating frequency: 1s ON, 9s OFF)
<Motor load*>
Min. 2
×105 (N.O. side, Inrush 25A, steady 5A at 14V DC)
Min. 105 (N.O. side, 20A 14V DC at motor lock)
Min. 2
×105 (N.C. side, 20A 14V DC at brake current) (Operating frequency: 0.5s ON, 9.5s OFF)
Conditions
Conditions for operation, transport and storage*2
Ambient temp: –40
°C to +85°C –40°F to +185°F
Humidity: 5% R.H. to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed
6 cpm (at rated load)
Mass
Approx. 4g .14 oz
Characteristics
Item
Specications
Rating
Max. carrying current (12V DC initial)*1
N.O.: 25A for 1 minutes, 15A for 1 hour (at 20
°C 68°F)
Expected life
Electrical
<Wiper motor load (L = Approx. 1mH)>
N.O. side: Min. 5
×105 (Inrush 25A, steady 6A at 14V DC)
N.C. side: Min. 5
×105 (12A 14V DC at brake current)
(Operating frequency: 1s ON, 9s OFF)
All Rights Reserved C
OPYRIGHT Panasonic Electric Works Co., Ltd.