CMP350 SERIES
Quad output
[ 2 YEAR WARRANTY ]
10 x 5 inch footprint with 1.75 inch low profile
EN61000-3-2 compliant
Current sharing
Individually protected outputs
Power fail signals
350W with 300LFM
EN55022, EN55011 conducted emissions level B
UL, VDE and CSA safety approvals
The CMP350 series is a 350W universal input AC/DC power supply in a 10 x 5 x
1.75 inch package. The series has the lowest standard 350W profile in the
industry, input harmonic current emission correction as standard, current sharing
and has 3.3V models to support the industry's transition from 5V to lower
operating voltages. The CMP350 provides 350W of output power with 300LFM of
forced air. Standard features include isolated outputs with individual overvoltage
and overload protection on each output. The series has an enclosure with end-
mounted fans option that does not change the overall height. The series, with full
international safety approval and the CE mark, meets conducted emissions
EN55022 level B and has immunity compliance to EN61000-4-2,-3,-4, -5, -6. The
CMP350 series is designed for use in medium power data networking, computer
and telecom applications such as hubs, routers, file servers, graphic workstations
and mass storage peripherals. It is also suitable for industrial, test and office
applications.
SPECIFICATION
All specifications are typical at nominal input, full load at 25
°
C unless otherwise stated
PAGE 62
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
Harmonic current
emission correction
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-3-2
Level B
Level A
Compliant
EN61000-4-2
EN61000-4-2
EN61000-4-5
EN61000-4-4
EN61000-4-3
EN61000-4-6
Level 3
Level 3
Level 3
Level 3
Level 3
Level 3
GENERAL SPECIFICATIONS
Hold-up time
110VAC, 60Hz, 350W
16ms
Efficiency
75% typical
Isolation voltage
Input/output
Input/chassis
Output/output
3000VAC
1500VAC
50VDC
Switching frequency
150kHz
Approvals and
standards
EN60950, VDE0805, UL1950,
CSA C22.2 No. 950
Weight
2.0kg (4.4Ibs)
Size
(See Note C)
Open frame
Enclosed
10.0 x 5 x 1.75 inches
10.5 x 5 x 1.75 inches
MTBF
MIL-HDBK-217F
Bellcore TR-NWT-332
212,707 hours
959,870 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient, FL
Cooling
+50°C to +70°C,
ambient
Non-operating
0°C to +50°C
300LFM airflow required
Derate to 50% load
on all channels
-40°C to +85°C
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
Non-operating
10,000 feet max.
30,000 feet max.
Vibration (See Note 15)
5Hz to 500Hz
2.4G rms peak
OUTPUT SPECIFICATIONS
Output accuracy
±1.0%
Total regulation
(Line and load)
Main and auxiliary V1 output
Auxiliary output (V2)
Auxiliary output (V3)
±1.0%
±6.0%
±5.0%
Transient response
Main output
25% step load
change at 1A/μs
2.0% max. dev.,
500μs recovery
Temperature coefficient
±0.02%/°C
Ripple and noise
(See Note 3)
0Hz to 20MHz
50mV pk-pk
or 1.0%
Overvoltage protection
Latching
See table
Short circuit protection
All channels
Continuous,
auto recovery
Overload protection
All channels
Yes
Thermal protection
Auto shutdown,
auto recovery
Current sharing
Main output and
Aux. 1 (5V and 3V3)
±10% of rating
INPUT SPECIFICATIONS
Input voltage range
Universal
(30s brown-out at 85VAC)
90 to 264VAC
Input frequency range
47Hz to 63Hz
Input surge voltage
300VAC
20ms
Inrush current
264VAC, cold start
75A max.
Safety ground
leakage current
0.72mA
Input current
110VAC, 350W
4.2Arms max.
Input fuse
UL, IEC approved
6.3A 250V
Power factor
110/220VAC full load
0.97 min.