OUTPUT SPECIFICATIONS
Line regulation
LL to HL, FL
Single outputs
Multi's: +5.1V output
Multi's: aux. outputs
±0.2%
±0.2%
±1.0%
Total regulation
NL to FL (Note 5)
Single outputs
Multi's: +5.1V output,
Multi's: aux. outputs
±5.0%
±5.0%
See table
Overshoot/undershoot
At turn-on
10% max.
Transient response
(Single output model)
+5.1V output
(50% FL to
100% FL step)
±250mV max. dev.,
1ms recovery to 1%
Temperature coefficient All outputs
±0.02%/°C
Overvoltage protection
+5.1V output only
6.25V ±0.75V
Output power limit
Primary power limited
90W Pin max.
50W Pout min.
Short Circuit Protection
Continuous with
auto-restart
INPUT SPECIFICATIONS
Input voltage range
Note 1
85 to 264VAC
Input frequency range
47 to 440Hz
Input surge current
110VAC
230VAC
12A max.
30A max.
Safety ground
leakage current
110VAC, 60Hz
230VAC, 50Hz
0.2mA
0.4mA
ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS
Radiated emissions
Conducted emissions
Electrostatic discharge
Electrostat. air discharge IEC801-2
RF field susceptibility
Electrical fast
transients/bursts
Surge susceptibility
EN55022, EN55011, FCC
EN55022, EN55011, FCC
EN61000-4-2
Level B
Level A
Level 4
Level 3
Level 3
Level 3
IEC801-3
EN61000-4-4
EN61000-4-5
Level 3
GENERAL SPECIFICATIONS
Hold-up time
110VAC
230VAC
12ms
110ms
Efficiency
110VAC and 230VAC
70% typical
Isolation voltage
Input/output
Input/chassis
3000VAC
1500VAC
Switching frequency
Variable
20kHz to 70kHz
Approvals and
standards
VDE0805, EN60950
IEC950, IEC1010, UL1950
BABT, CSA C22.2 No. 950
Case material
ABS plastic
Material flammability
UL94V-0
Weight
800g (28oz)
MTBF
MIL-HDBK-217E
100,000 hours min.
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating
Non-operating
0°C to 40°C ambient
Peak (0°C to 40°C, max. 60s)
0°C to +40°C
–40°C to +85°C
40W
50W
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
Non-operating
10,000 feet max.
40,000 feet max.
Vibration, 5Hz to 500Hz See Note 8
2.4G rms (approx)
Recommended for new design-ins
CL40 SERIES
Single and triple output
[ 2 YEAR WARRANTY ]
85VAC to 264VAC universal input range
Pre-approved SELV power solution
Up to 40W continuous output power
Up to 50W peak output power
UL, CSA, VDE and BABT approved
VDE0871-A conducted noise performance
Stand alone "listed" equipment
The CL40 series is a family of 40W (50W peak) external switching power
supplies. The CL40 enables the system specifier to optimise the design for
several reasons. Firstly, because the power supply offers pre-approved SELV
(Safety Extra Low Voltage) outputs, the submission of the apparatus for safety
approval is simplified. This represents a significant saving of time and money.
Secondly, the task of integrating the power supply into the mechanical design is
eliminated, presenting further savings in time and money by ensuring a shorter
and simpler design cycle. This means that your product gets to market faster.
These advantages are complemented by universal input, CE mark, IEC950, UL,
CSA, VDE and BABT approvals, to complete a worldwide packaged power
solution suitable for a wide variety of low power, desktop applications.
SPECIFICATION
All specifications are typical at nominal input, full load at 25
°
C unless otherwise stated
PAGE 1