CAT803, CAT809, CAT810
6
Doc. No. 3004, Rev. X
2007 by Catalyst Semiconductor, Inc.
Characteristics subject to change without notice
0V
CAT803, CAT809
5V
0V
5V
RESET
RESET
T
D
V
TH
V
CC
T
R
(140msec
minimum)
CAT810
0V
5V
DETAILED DESCRIPTIOnS
RESET TIMInG
The reset signal is asserted LOW for the CAT803/
CAT809 and HIGH for the CAT80 when the power
supply voltage falls below the threshold trip voltage and
remains asserted for at least 40ms after the power
supply voltage has risen above the threshold.
figure 2. Maximum Transient Duration Without Causing a Reset Pulse vs. Reset Comparator Overdrive
T
V
CC
TRAnSIEnT RESPOnSE
The CAT803/CAT809/CAT80 protect
μ
Ps against
brownout failure. Short duration transients of 4
μ
sec
or less and 00mV amplitude typically do not cause a
false RESET.
Figure 2 shows the maximum pulse duration of negative-
going V
CC
transients that do not cause a reset condition.
figure 1. Reset Timing Diagram
As the amplitude of the transient goes further below
the threshold (increasing V
TH
- V
CC
), the maximum
pulse duration decreases. In this test, the V
CC
starts
from an initial voltage of 0.5V above the threshold and
drops below it by the amplitude of the overdrive voltage
(V
TH
- V
CC
).