Aluminum Electrolytic Capacitors/FA
Aluminum Electrolytic Capacitors
(Type Radial Lead)
Series:
FA
Type:
A
(Radial Leads)
Style:
04/J IS C 5141
I
Explanation of Part Numbers
I
S pec ific ations
Operating temperature range –55 to 105°C
* (120 Hz/+20°C) ** Max.
I
Dimensions in mm
(not to scale)
I
Frequenc y Correc tion Fac tor for Ripple Current
Frequency (Hz)
Working Voltage(V DC)
Capacitance (μF)
60
120
1k
10k
100k
60
390
1,200
2,700
to
to
to
to 15,000
330
1,000
2,200
0.55
0.70
0.75
0.80
0.65
0.75
0.80
0.85
0.85
0.90
0.90
0.95
0.90
0.95
0.95
1.00
1.0
1.0
1.0
1.0
6.3 to 63
L
L
≤
16: L + 1.0 max.
L
≥
20: L + 2.0 max.
14 mn.
P
±
0
φ
d
±
0
P
±
0
φ
D+0.5 max.
φ
D+0.5 max.
PVC Sleeve
Vent
–
+
Body Dia.
φ
D
Body Length L
Lead Dia.
φ
D
Lead Space P
8 10 12.5 x
— —
≤
25
≥
30 — —
0.6 0.6 0.6 0.8 0.8 0.8
3.5 5.0 5.0 5.0 7.5 7.5
16 18
Rated working voltage
6.3 to 63 V DC
Nomnal capacitance range
68 to 15,000 μF
Capacitance tolerance
±20% (120 Hz/+20°C)
tan
δ
W.V. (V)
6.3
10
16
25
35
50
63
tan
δ
**
0.22
0.19
0.16
0.14
0.12
0.10
0.08
DCleakage current
I
≤
0.01 CV(μA) after 2 mnutes application of
rated working voltage at +20°C
Impedance at –10°C, 100 kHz
≤
200% of initial
specified value at +20°C, 100 kHz. (Impedance
ratio at 100 kHz)
Characteristics at low
temperature
Endurance:
Capacitance change
tan
δ
DCleakage current
±20% of initial measured value
≤
200% of initial specified value
≤
initial specified value
After storage for 1,000 hours at +105±2°C wth
no voltage applied and then being stabilized at
+20°C, capacitor shall meet the limts specified
in “Endurance.”
Shelf life
Product Code
Series Code
N Capacitance Code
EFO
Radial Lead Type
E
1
E
2
U
3
8
9
10
Option
11
12
R.W. Voltage Code
6
7
F
4
A
5
I
Features
Smaller than Series HFQ
Low impedance (20 to 40 less volume than Series HFQ)
Long life: 2,000 to 5,000 hours at +105°C
I
Rec ommended Applic ations
Power supplies, lighting, robots, industrial controls,
telecommunications equipment
Panasonic
Design and specifications are subject to change wthout notice. Ask factory for technical specifications before purchase and/or use.
Whenever a doubt about safety issues arises fromthis product, please informus immediately for technical consultation.