Time ranges
0.15-
1.5 - 60 s
15.0 - 600 s
0 to +10% on max.
min. actual time
≤
min.
set time
6 s
Time range accuracy
Repeatability deviation
Time variation
Within rated power supply
and ambient temperature
Reset
Time and/or relay
≤
1%
≤
0.05%/V
≤
0.2%/°C
Power supply interruption min.
250 ms
C 108, C 208, C 118, C 218
C 101, C 201, C 111, C 211
C 108, C 101, C 118, C 111
C 208, C 201, C 218, C 211
Output
Basic electrical insulation
Contact ratings
(AgCdO)
Resistive loads
SPDT relay
250 VAC (rms) (contact/electronics)
μ (micro gap)
10 A/250 VAC (2500 VA)
1 A/250 VDC (250 W)
10 A/25 VDC (250 W)
DPDT relay
250 VAC (rms) (contacts/elec., contact/contact)
μ (micro gap)
8 A/250 VAC (2000 VA)
0.4 A/250 VDC (100 W)
4 A/25 VDC (100 W)
2.5 A/230 VAC
5 A/24 VDC
≥
30 x 10
6
operations
≥
2.5 x 10
5
operations (at max. load)
≤
7200 operations/h
AC 1
DC 1
or
Small inductive loads AC 15 2.5 A/230 VAC
DC 13 5 A/24 VDC
≥
30 x 10
6
operations
AC 1
≥
2.5 x 10
5
operations (at max. load)
≤
7200 operations/h
Mechanical life
Electrical life
Operating frequency
Insulation voltages
Rated insulation voltage
Rated transient protection volt.
4 kV (1.2/50 μs) (contact/electronics) (IEC 60664)
≥
2.0 kVAC (rms) (contact/electronics)
≥
2.0 kVAC (rms) (contact/electronics)
4 kV (1.2/50 μs) (contact/electronics) (IEC 60664)
Power supply AC types
Rated operational voltage
through pins 2 & 10
or pins 2 & 7
Installation cat. III (IEC 60664)
220
220 VAC + 15/- 20%,
45 to 65 Hz
120 VAC + 15/- 20%,
45 to 65 Hz
24 VAC + 15/- 20%,
45 to 65 Hz
≥
10 ms
None
120
024
Dropout tolerance
Rated insulation voltage
Rated transient protection volt. 4 kV (1.2/50 μs) @ 220 VAC
2.5 kV (1.2/50 μs) @ 120 VAC
800 V (1.2/50 μs) @ 24 VAC
(line/neutral)
Installation cat. III (IEC 60664)
24 VDC + 15/- 20% (pin 2 pos.)
Power supply DC type
Rated operational volt.
024
Rated insulation voltage
Rated transient protection volt. 800 V (1.2/50 μs)
Consumption
AC supply
DC supply
Power ON delay
Power OFF delay
None
60 mA @ 50 Hz/70 mA @ 60 Hz
1 W
≤
200 ms
≥
250 ms
Indication for
Output ON
Environment
Degree of protection
Pollution degree
Operating temperature
Storage temperature
Weight
Approvals
LED. red
IP 20 B
2 (IEC 60664)
-20° to +50°C (-4° to +122°F)
-50° to +85°C (-58° to +185°F)
85 g
UL, CSA
Time Specifications
Output Specifications
Supply Specifications