DC/DC CONVERTERS 30W Wide Input DC/DC Converters
1
2 YEAR WARRANTY
BXA30 Series
Tr i pl e o u t pu t
Pin-compatible with BXA15 series
Designed to meet telecom power supply interface
standard ETS300-132-2
UL, CSA and VDE approvals
VDE0878 and EN55022 conducted emissions level A
EN61000-4-2, -3, -4, -5, -6 immunity compliant
Fixed frequency operation at 350kHz
MTBF in excess of 7,005,000 hours (demonstrated)
Basic insulation system
The BXA30 triple output Series, comprising 2 different models, has been conceived as an
applications-specific range of DC/DC converters, specifically addressing telecommunications,
industrial electronics, test equipment, mobile telecommunications and distributed power
applications. The series offers two wide input voltage ranges, 18-36VDC and 36-75VDC.
Designed to meet ETSI telecoms interface standards ETS300-132-2 and BTR2511, together
with internal filtering to EN55022 level A, safety approval to EN60950 and UL1950, and basic
insulation of 1500VDC, the 48VDC model is ideal for telecommunications applications.
The 24V model is particularly suited to industrial, mobile telecom and test equipment
applications, featuring EN61000-4-2, -3, -4, -5 and -6 immunity compliant. Other features
include low output ripple, overvoltage protection, short circuit protection, remote enable.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
EMC CHARACTERISTICS
Conducted emissions
EN55022, FCC part 15 (Note 3) Level A
EN55022, FCC part 15 (Note 4) Level B
VDE0878 (Note 3) (48V)
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Level A
Level A
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
Perf. criteria 2
GENERAL SPECIFICATIONS
Efficiency
See table
Isolation voltage
Basic insulation
Input/output
Input/case, 48V models
1500VDC
1500VDC
Switching frequency
Fixed
350kHz, nom.
Approvals and
standards
(See Note 11)
VDE0805, EN60950
EN41003, IEC950, UL1950
CSA C22.2 No. 950
Case material
Aluminum substrate
with plastic case
Material flammability
UL94V-0
Weight
130g (4.6oz)
MTBF (See Note 9)
Demonstrated @ 25°C
7,005,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Baseplate operating
temperature,
(See Notes 5, 7)
Non-operating
-25°C to +100°C
-55°C to +100°C
Thermal impedance
Free air convection,
baseplate to air
With heatsink (See Note 7)
6.5°C/W
5.2°C/W
OUTPUT SPECIFICATIONS
Output power
30W
Line regulation
(See Note 1)
Main output
Auxiliary output
±0.5%
±2.0%
Load regulation
(See Note 2)
Main output
Auxiliary output
±1.0%
±3.0%
Ripple and noise
(20MHz bandwidth)
Main output
75mV pk-pk
15mV rms
100mV pk-pk
20mV rms
Auxiliary outputs
Temperature coefficient
±0.02%/°C
Overvoltage protection
Transient, all outputs
135% Vout init.
Short circuit protection
All outputs
(See BXA15/30 Design Note 101)
Yes
Transient response
25% to 100% load, all outputs
10%
Voltage accuracy
Main output
Auxiliary output
±1.5%
±3.0%
Load cross regulation
20% to 100% load
Main: output
Auxiliary: output
50% to 100% load, main, >20% aux.
Main output
Auxiliary output
1.0%
10%
1.0%
4.0%
Minimum load
(See Note 10)
Main output for auxiliary
regulation
>10%
INPUT SPECIFICATIONS
Input voltage range
24Vin nominal
48Vin nominal
18 to 36VDC
36 to 75VDC
Reverse voltage prot.
(See Note 6)
Yes
Max. input rise and
fall time
48V
5V/ms
ETS300-132
Remote ON/OFF
Logic compatibility
ON
OFF
CMOS/TTL
Open circuit
<1VDC
SPECIFICATIONS
File Name: BXA30T.PDF Rev: 02 Oct 2002