      Monitor Command Stack Pointer B (fixed location)
      Monitor Command Stack B (1K words)
      0800-3FFF
      Not Used (4K words)
      Monitor Command Stack A (1K words)
      3000-3FFF
      0400-07FF
      Monitor Data Stack B (4K words)
      Not Used
      2000-2FFF
      0300-03FF
      Monitor Data Stack A (4K words)
      Selective Monitor Lookup Table (fixed area)
      1000-1FFF
      0280-02FF
      Not Used (1K words)
      Not Used
      0C00-0FFF-
      0108-027F
      Monitor Data Stack Pointer B (fixed location)
      0107
      Not Used
      0104-0105
      Monitor Data Stack Pointer A (fixed location)
      0103
      Monitor Command Stack Pointer A (fixed location)
      0102
      Not Used
      0000-0101
      DESCRIPTION
      ADDRESS
      (HEX)
      0106
      TABLE 32. TYPICAL SELECTIVE MESSAGE
      MONITOR
      MEMORY MAP (SHOWN FOR 16K RAM)
      Refer to FIGURE 8 for an illustration of the Selective Message
      Monitor operation. Upon receipt of a valid Command Word, the
      BU-61582 will reference the Selective Monitor Lookup Table (a
      fixed block of addresses) to check for the condition
      (disabled/enabled) of the current command. If disabled, the BU-
      61582 will ignore (and not store) the current message; if enabled,
      the BU-61582 will create an entry in the Monitor Command Stack
      at the address location referenced by the Monitor Command
      Stack Pointer.
      Similar to RT mode, The SP’ACE stores a Block Status Word,
      16-bit Time Tag Word, and Data Block Pointer in the Message
      Descriptor, along with the received 1553 Command Word follow-
      ing reception of the Command Word. The SP’ACE writes the
      Block Status and Time Tag Words at both the start and end of the
      message. The Monitor Block Status Word contains indications of
      message in-progress or message complete, bus channel,
      Monitor Data Stack Rollover, RT-to-RT transfer and RT-to-RT
      transfer errors, message format error, and other error conditions.
      TABLE 26 shows the Message Monitor Block Status Word. The
      Data Block Pointer references the first word stored in the Monitor
      Data Stack (the first word following the Command Word) for the
      current message. The BU-61582 will then proceed to store the
      subsequent words from the message (possible second
      Command Word, Data Word(s), Status Word(s) into consecutive
      locations in the Monitor Data Stack).
      The size of the Monitor Command Stack is programmable to
      256, 1K, 4K, or 16K words. The Monitor Data Stack size is pro-
      grammable to 512, 1K, 2K, 4K, 8K, 16K, 32K, or 64K words.
      Monitor interrupts may be enabled for Monitor Command Stack
      Rollover, Monitor Data Stack Rollover, and/or End-of-Message
      conditions. In addition, in the Word Monitor mode there may be
      an interrupt enabled for a Monitor Trigger condition.
      15
      13
      0
      BLOCK STATUS WORD
      TIME TAG WORD
      DATA BLOCK POINTER
      RECEIVED COMMAND
      WORD
      CONFIGURATION
      REGISTER #1
      MONITOR COMMAND
      STACK POINTERS
      MONITOR
      COMMAND STACKS
      CURRENT
      AREA B/A
      MONITOR DATA
      STACKS
      MONITOR DATA
      BLOCK #N + 1
      MONITOR DATA
      BLOCK #N
      CURRENT
      COMMAND WORD
      MONITOR DATA
      STACK POINTERS
      IF THIS BIT IS "0" (NOT SELECTED)
      NO WORDS ARE STORED IN EITHER
      THE COMMAND STACK OR DATA STACK.
      IN ADDITION, THE COMMAND AND DATA
      STACK POINTERS WILL NOT BE UPDATED.
      NOTE
      SELECTIVE MONITOR
      LOOKUP TABLES
      SELECTIVE MONITOR
      ENABLE
      (SEE NOTE)
      OFFSET BASED ON
      RTA4-RTA0, T/R, SA4
      MONITOR DATA STACK
      50% ROLLOVER INTERRUPT
      MONITOR DATA STACK
      100% ROLLOVER INTERRUPT
      MONITOR COMMAND STACK
      50% ROLLOVER INTERRUPT
      MONITOR COMMAND STACK
      100% ROLLOVER INTERRUPT
      FIGURE 8. SELECTIVE MESSAGE MONITOR OPERATION
      相關(guān)PDF資料
      PDF描述
      BU-61583D3-150 2 CHANNEL(S), 1M bps, MIL-STD-1553 CONTROLLER, CQIP70
      BU-61583D3-151K 2 CHANNEL(S), 1M bps, MIL-STD-1553 CONTROLLER, CQIP70
      BU-61583D3-160L 2 CHANNEL(S), 1M bps, MIL-STD-1553 CONTROLLER, CQIP70
      BU-61583D3-160 2 CHANNEL(S), 1M bps, MIL-STD-1553 CONTROLLER, CQIP70
      BU-61583D3-161 2 CHANNEL(S), 1M bps, MIL-STD-1553 CONTROLLER, CQIP70
      相關(guān)代理商/技術(shù)參數(shù)
      參數(shù)描述
      BU-61585 制造商:未知廠家 制造商全稱(chēng):未知廠家 功能描述:MIL-STD-1553 Components |ACE
      BU-61586 制造商:未知廠家 制造商全稱(chēng):未知廠家 功能描述:MIL-STD-1553 Components |ACE
      BU61586V6-300 制造商:DDC 功能描述:MIL-STD-1553/ARINC BUS CONTROLLER/RTU, 70 Pin, Flat Pack
      BU-61588 制造商:未知廠家 制造商全稱(chēng):未知廠家 功能描述:MINIATURE ADVANCED COMMUNICATION ENGINE (MINI-ACE) AND MINI-ACE PLUS
      BU-61588F0 制造商:未知廠家 制造商全稱(chēng):未知廠家 功能描述:MINIATURE ADVANCED COMMUNICATION ENGINE (MINI-ACE) AND MINI-ACE PLUS