    18
    Error bit in its internal Status Register, regardless of whether
    or not corresponding bit in the illegalization RAM has been
    set. If the next message is a Transmit Status or Transmit Last
    Command mode code, the ACE will respond with its
    Message Error bit set.
    PROGRAMMABLE BUSY
    As a means of providing compliance with Notice 2 of MIL-STD-
    1553B, the BU-65170/61580 RT provides a software controllable
    means for setting the Busy Status Word bit as a function of sub-
    address. By a Busy Lookup Table in the BU-65170/61580
    address space, it is possible to set the Busy bit based on com-
    mand broadcast/own address, T/R bit, and subaddress. Another
    programmable option, allows received Data Words to be either
    stored or not stored for messages, when the Busy bit is set.
    OTHER RT FUNCTIONS
    The BU-65170/61580 allows the hardwired RT Address to be
    read by the host processor. Also, there are options for the RT
    FLAG Status Word bit to be set under software control and/or
    automatically following a failure of the loopback self-test. Other
    software controllable RT options include software programmable
    RT Status and RT BIT words, automatic clearing of the Service
    Request Status Word bit following a Transmit Vector Word mode
    command, capabilities to clear and/or load the Time Tag Register
    following receipt of Synchronize mode commands, options
    regarding Data Word transfers for the Busy and/or Message
    Error (Illegal) Status Word bits, and for handling of 1553A and
    reserved mode codes.
    MONITOR (MT) ARCHITECTURE
    The BU-61580 provides three bus monitor (MT) modes:
    (1) The “AIM-HY” (default) or “AIM-HY'er” Word Monitor mode.
    (2) A Selective Message Monitor mode.
    (3) A Simultaneous Remote Terminal/Selective Message Monitor
    mode.
    The strong recommendation for new applications is the use of
    the Selective Message Monitor, rather than the Word Monitor.
    Besides providing monitor filtering based on RT Address, T/R bit,
    and Subaddress, the Message Monitor eliminates the need to
    determine the start and end of messages by software. The devel-
    opment of such software tends to be a tedious task. Moreover, at
    run time, it tends to entail a high degree of CPU overhead.
    WORD MONITOR
    In the Word Monitor mode, the BU-61580 monitors both 1553
    buses. After initializing the Word Monitor and putting it on-line the
    BU-61580 stores all Command, Status, and Data Words
    received from both buses. For each word received from either
    bus, the BU-61580 stores a pair of words in RAM. The first word
    is the 16 bits of data from the received word. The second word is
    the Monitor Identification (ID), or “Tag” word. The ID Word con-
    tains information relating to bus channel, sync type, word validi-
    ty, and interword time gaps. The BU-61580 stores data and ID
    words in a circular buffer in the shared RAM address space.
    TABLE 23 shows the bit mapping for the Monitor ID word.
    MONITOR TRIGGER WORD
    There is a Trigger Word Register that provides additional flexibil-
    ity for the Word Monitor mode. The BU-61580 stores the value of
    the 16-bit Trigger Word in the MT Trigger Word Register. The con-
    tents of this register represent the value of the Trigger Command
    Word. The BU-61580 has programmable options to start or stop
    the Word Monitor, and/or to issue an interrupt request following
    receipt of the Trigger Command Word from the 1553 bus.
    SELECTIVE MESSAGE MONITOR MODE
    The BU-61580 Selective Message Monitor provides features to
    greatly reduce the software and processing burden of the host
    CPU. The Selective Message Monitor implements selective mon-
    itoring of messages from a dual 1553 bus, with the monitor fil-
    tering based on the RT Address, T/R bit, and Subaddress fields
    of received 1553 Command Words. The Selective Message
    Monitor mode greatly simplifies the host processor software by
    distinguishing between Command and Status Words. The
    Selective Message Monitor maintains two stacks in the BU-
    61580 RAM: a Command Stack and a Data Stack.
    Simultaneous RT/Message Monitor Mode
    The Selective Message Monitor may function as a purely passive
    monitor or may be programmed to function as a simultaneous
    RT/Monitor. The RT/Monitor mode provides complete Remote
    Terminal (RT) operation for the BU-61580's strapped RT address
    and bus monitor capability for the other 30 nonbroadcast RT
    addresses. This allows the BU-61580 to simultaneously operate
    as a full function RT and “snoop” on all or a subset of the bus
    activity involving the other RTs on a bus. This type of operation
    is sometimes needed to implement a backup bus controller. The
    combined RT/Selective Monitor maintains three stack areas in
    the BU-61580 address space: an RT Command Stack, a Monitor
    Command Stack, and a Monitor Data Stack. The pointers for the
    various stacks have fixed locations in the BU-61580 address
    space.
    WC4/MC4
    0(LSB)
    SA0
    1
    SA1
    2
    0
    SA2
    3
    SA3
    4
    SA4
    5
    T/R
    6
    BROADCAST/OWN_ADDRESS
    7
    1
    8
    1
    9
    0
    10
    0
    12
    0
    13
    0
    14
    0
    15(MSB)
    DESCRIPTION
    BIT
    11
    TABLE 29. ILLEGALIZATION RAM ADDRESS DEFINITION
    相關(guān)PDF資料
    PDF描述
    BU-61581V5-160Z 2 CHANNEL(S), 1M bps, MIL-STD-1553 CONTROLLER, CDFP70
    BU-61581V6-160Q 2 CHANNEL(S), 1M bps, MIL-STD-1553 CONTROLLER, CDFP70
    BU-61585G0-140K 2 CHANNEL(S), 1M bps, MIL-STD-1553 CONTROLLER, CDSO70
    BU-61585G1-140Z 2 CHANNEL(S), 1M bps, MIL-STD-1553 CONTROLLER, CDSO70
    BU-61585G1-160Y 2 CHANNEL(S), 1M bps, MIL-STD-1553 CONTROLLER, CDSO70
    相關(guān)代理商/技術(shù)參數(shù)
    參數(shù)描述
    BU-61581V6-100 制造商:未知廠家 制造商全稱:未知廠家 功能描述:MIL-STD-1553/ARINC Bus Controller/RTU
    BU-61581V6-110 制造商:未知廠家 制造商全稱:未知廠家 功能描述:MIL-STD-1553/ARINC Bus Controller/RTU
    BU-61581V6-120 制造商:未知廠家 制造商全稱:未知廠家 功能描述:MIL-STD-1553/ARINC Bus Controller/RTU
    BU-61581V6-200 制造商:未知廠家 制造商全稱:未知廠家 功能描述:MIL-STD-1553/ARINC Bus Controller/RTU
    BU-61581V6-300 制造商:未知廠家 制造商全稱:未知廠家 功能描述:MIL-STD-1553/ARINC Bus Controller/RTU