JUL 05, 2006 revised to DEC 05, 2006
Page 1 of 6
www.power-one.com
BLP30 AC-DC Series Data Sheet
30 Watts
Description
The BLP30 Series’ economical and compact construction provides single or three-output AC to DC power
conversion to meet the requirements of most commercial and industrial applications.
Single-Output Model Selection
Model
Nominal
Output Voltage
(VDC)
5V
Min-Max Output
Current (Amps),
Convection
Min-Max Output
Current (Amps),
Forced Air
1
Peak Output
Current
(Amps)
2
Total
Regulation
(%)
3
±
2
Ripple &
Noise
pk-pk %
4
BLP30-1005G
0 – 5
0 – 6
7.2
1
BLP30-1012G
12V
0 – 2.1
0 – 2.5
3.0
±
2
1
BLP30-1024G
24V
0 – 1.0
0 – 1.25
1.5
±
2
0.6
Triple-Output Model Selection
Model
Nominal
Output Voltage
(VDC)
+5V
Min-Max Output
Current (Amps),
Convection
Min-Max Output
Current (Amps),
Forced Air
1
Peak Output
Current
(Amps)
2
Total
Regulation
(%)
3
±
2
Ripple &
Noise
pk-pk %
4
0.2 – 2.5
0.2 – 3.5
5
1%
BLP30-3000G
+12V
0.1 – 1.2
0.1 – 2.0
3
±
5
1%
-12V
0.0 – 0.3
0.0 – 0.5
1
±
5
1%
1
10 CFM or 260 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm) cross-sectional area with
power supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC input to the DC output.
2
Peak current duration for less than 30 seconds with a max duty cycle of 10%.
3
At 25
°
C ambient including voltage set point tolerance, line, and load regulation
4
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, measured with a twisted pair differentially
across a 10 μF E-cap and a 0.1 μF ceramic cap in parallel. The point of measurement is within 1 cm of the output connection.
Applications
Datacom (hubs, routers)
POS terminals
Industrial
Cable modems
External disk storage
Medical instrumentation
Computers
Features
RoHS compliant for all six substances
2” x 4” footprint
Component height less than 1”
25 W rating with natural convection cooling
30 W rating with 10 CFM airflow
Compliance to EMI Class B
Universal AC input
Short-circuit protection
Overvoltage protection
CE marked to Low Voltage Directive (Pending)
Compliance to EN61000-4-2/-3/-4/-5/-6/-8/-11
Two-year warranty