Mini-Circuits
P.O. Box 350166, Brooklyn, New York 11235-0003 (718) 934-4500 Fax (718) 332-4661 The Design Engineers Search Engine
Provides ACTUAL Data Instantly at
Notes: 1. Performance and quality attributes and conditions not expressly stated in this specification sheet are intended to be excluded and do not form a part of this specification sheet. 2. Electrical specifications
and performance data contained herein are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. 3. The parts covered by this specification sheet are subject to
Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard
Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp.
For detailed performance specs
& shopping online see web site
minicircuits.com
IF/RF MICROWAVE COMPONENTS
Maximum Ratings
Typical Performance Data
Frequency
(MHz)
Insertion Loss
(dB)
Low Pass Filter Electrical Specications
Operating Temperature
-55°C to 100°C
Storage Temperature
-55°C to 100°C
RF Power Input
0.5W max.
Return Loss
(dB)
Frequency
(MHz)
Group Delay
(nsec)
_
x
σ
Low Pass Filter
REV. A
M98898
BLP-600-75
090818
75
DC to 580 MHz
PASSBAND
(MHz)
fco (MHz)
Nom.
STOPBAND
(MHz)
VSWR
(:1)
(loss < 1 dB)
(loss 3 dB)
(loss > 20 dB)
(loss > 40 dB)
Passband
Typ.
Stopband
Typ.
DC-580
640
840-1120
1120-2000
1.7
18
electrical schematic
PLP-600-75
INSERTION LOSS
0
20
40
60
80
100
1
10
100
1000
10000
FREQUENCY(MHz)
INSERTION
LOSS
(dB)
at RF level of 0 dBm
PLP-600-75
RETURN LOSS
0
10
20
30
40
50
1
10
100
1000
10000
FREQUENCY(MHz)
R
E
TU
R
N
LO
S
(d
B
)
at RF level of 0 dBm
PLP-600-75
GROUP DELAY
0
1
2
3
4
5
0
240
480
720
960
1200
FREQUENCY (MHz)
G
R
O
U
P
D
E
LA
Y
(n
se
c)
at RF level of 0 dBm
typical frequency response
Coaxial
BLP-600-75+
BLP-600-75
+ RoHS compliant in accordance
with EU Directive (2002/95/EC)
The +Sufx identies RoHS Compliance. See our web site
for RoHS Compliance methodologies and qualications.
10.00
0.03
0.01
39.03
10.00
1.68
88.80
0.06
0.02
20.33
11.91
1.58
167.50
0.17
0.03
15.95
14.07
1.73
246.30
0.23
0.02
14.87
16.62
1.77
325.00
0.24
0.02
17.52
19.64
1.66
403.80
0.23
0.04
24.71
23.20
1.61
482.50
0.45
0.10
16.54
27.40
1.68
580.00
0.67
0.11
18.62
32.00
1.65
640.00
3.15
1.32
5.36
38.24
1.65
700.00
11.10
2.40
1.10
45.17
1.65
728.00
15.12
2.59
0.69
53.36
1.65
756.00
19.01
2.76
0.52
63.04
1.66
784.00
22.88
2.93
0.40
74.46
1.66
812.00
26.53
3.06
0.34
87.96
1.65
840.00
29.84
3.26
0.32
103.91
1.65
868.00
33.13
3.50
0.28
122.75
1.65
918.40
39.24
4.03
0.25
145.00
1.66
968.80
44.53
4.60
0.23
171.29
1.67
1019.20
50.42
5.97
0.22
202.35
1.68
1059.60
56.66
9.07
0.22
235.74
1.71
1120.00
61.58
9.70
0.22
278.48
1.77
1170.00
64.81
7.30
0.22
324.43
1.84
1273.80
71.86
7.17
0.21
383.24
1.98
1377.50
74.32
4.38
0.21
446.48
2.14
1481.30
77.46
5.00
0.21
527.43
2.48
1585.00
78.86
4.18
0.21
580.00
3.15
1688.80
76.30
5.08
0.21
640.00
3.69
1792.50
75.09
5.40
0.20
840.00
1.27
1896.30
71.89
4.47
0.20
1120.00
1.50
2000.00
71.83
6.46
0.19
1163.76
1.13
Applications
test equipment
lab use
video equipment
Features
rugged shielded case
other standard and custom BLP models available with
wide selection of fco
CASE STYLE: FF55
Connectors
Model
Price
Qty.
BNC
BLP-600-75(+)
$33.95 ea. (1-9)
Outline Dimensions (
)
Outline Drawing
inch
mm
R F IN
R F OUT
40 dB
20 dB
3 dB
1 dB
F R E QUE NC Y / F co
A
T
E
N
U
A
T
IO
N
,
d
B
DC
0.9
1
1.35
1.75
3
B
D
wt
.54
2.59 grams
13.72 65.79
40.0