10
T PC
BH 01/02/05/06/07
CPM-N — 5.08 Radial Leads 63/100/250/400 V-
HOW TO ORDER
BH 01
Type
4
Class
D
Voltage
0104
Capacitance Value
K
Tolerance
– –
Suffix
Schoop
Metallized film
e
L
0
.
H
5.08 (0.020)
-0.1 (0.004)
4
±
APPLICATIONS
Non-inductive, self-healing, metallized polyester film capacitor.
Insulated*thermoplastic casing, epoxy resin sealed with
stand-offs* Radial connections with a lead spacing of 5.08
mm.
*Flame retardant case according to UL 94 VO.
Some examples of use:
Supply decoupling, filter integrators, treatment of analog
signals, rejection of line perturbations, etc… Specifically
designed for working in severe environmental conditions
such as automotive applications: engine control, multiplexing
system, etc.
STANDARDIZATION
Generic specifications:
CEI 384-1/CECC 30000/UTE 83100
Sectional specifications:
CEI 384-2/CECC 30400/UTE 83151
On the LNZ list:
Complies with type CPM-N
RAQ2 production, equivalent AQAP-4 of NATO
MARKING
D 104 K E 49
DC nominal voltage
Nominal capacitance (EIA code)
Tolerance (EIA code)
Logo
Lot number
Example above: 63 V
DC
, 100nF, ±10%
Case L max.
01
7.5 (0.295)
02
7.5 (0.295)
05
7.5 (0.295) 12.0 (0.472) 6.0 (0.236) 0.5 (0.020)
06
7.5 (0.295)
9.6 (0.378) 6.0 (0.236) 0.5 (0.020)
07
7.5 (0.295)
8.0 (0.315) 5.0 (0.197) 0.5 (0.020) 8.2nF
≤
C
R
≤
1μF
H max.
6.5 (0.256) 2.5 (0.098) 0.5 (0.020)
8.0 (0.315) 3.2 (0.126) 0.5 (0.020) 5.6nF
≤
C
R
≤
330nF
e max. ± 0.02 Observations
1nF
≤
C
R
≤
220nF
39nF
≤
C
R
≤
2.2μF
18nF
≤
C
R
≤
100nF
DIMENSIONS:
millimeters (inches)
Schematic Cross Section
PERFORMANCE CHARACTERISTICS
Climatic category:
55/125/56 - Performance Class 2
Capacitance range:
C
R
1 nF to 2.2 μF (E12)
Tolerances on C
R
:
±5%, ±10%
(other values on request)
Nominal voltages:
V
R–
63/100/250/400 V
V
R~
40/63/160/200 V
Category voltage:
V
= 0.8 V
R-
at 100°C/0.5 V
R-
at 125°C
Test voltage:
V
e
= 1.6 V
R-
/2 s at 25°C
Tangent of loss angle: D.F. (see page 4)
Insulation resistance:
IR (see page 5)
Max. voltage gradient: (dv/dt)
R
(see page 5)
Life test:
C/C
≤
5% after 125°C/1000
h/0.5 V
R-
Thermal shock:
-55/+125°C/time cycle 1hr/500
cycles
C/C
≤
10%, D.F. 1kHz
≤
1%
Humidity test:
85°C/85% R.H./1000 h
C/C
≤
10%
V
R-
63
100
250
400
(dv/dt)
R
max
38
40
110
270