Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
Automatic Drain, Non-Relieving
Manual Drain, Non-Relieving
Ordering Information
See Ordering Information on following pages.
ISO Symbols
Automatic Drain, Relieving
Manual Drain, Relieving
5/96
N/UK
8.7.
063.01
Issue No.1 Revision 0
B74G
EXCELONSeries 74
Filter/Regulator
3/8", 1/2", 3/4" Port Sizes
G
EXCELON design allows in-line or modular
installation
G
High efficiency water and particle removal
G
Quick release bayonet bowl
G
Particle removal per ISO 8573-1, Class 5 and Class 3
G
Push to lock adjusting knob with tamper resistant
accessory
G
Patented quarter turn manual drain
Technical Data
Fluid: compressed air
Maximum Pressure:
Transparent bowl: 10 bar
Metal bowl: 17 bar
Operating Temperature*:
Transparent bowl: -20° to 50°C
Metal bowl: -20° to 80°C
*Air supply must be dry enough to avoid ice formation at temperatures below 2°C.
Manual drain connection: 7/16" X 24 TPI (1/4" male OD tube)
Automatic drain connection: 1/8 BSP
Typical flow with 10 bar inlet pressure, 6,3 set pressure and a
droop of 1 bar from set:
100 dm
3
/s
Automatic drain minimum operating conditions:
Pressure: 0,7 bar
Flow: 0,25 dm
3
/s
Gauge Ports:
14" PTF with PTF main ports
14" ISO Rc with ISO Rc main ports
18" ISO Rc with ISO G main ports
Materials:
Body: Aluminium
Bonnet: Aluminium
Valve: Brass
Bowl:
Plastic: Polycarbonate with zinc bowl guard
Metal: Aluminium
Metal bowl liquid level indicator lens:
Transparent nylon (Pyrex optional)
Element: Sintered plastic
Elastomers: Neoprene and Nitrile