CONT ACT S
Arrangement
SPST (1 Form A)
Ratings
Resistive load:
Max. switched power: 600 W or 4400 VA
Max. switched current: 20 A
Max. switched voltage: 150 VDC* or 400 VAC
*
Note: If switching voltage is greater than 30VDC,
special precautions must be taken.
Please contact the factory.
Rated Load
UL, CUR
20 A at 220 VAC, 100k cycles
1.5 HP 250 VAC, 100k cycles
Material
Silver cadmium oxide
Resistance
< 50 milliohms initially
(24 V, 1 A voltage drop method)
GENERAL DAT A
Life Expectancy
Minimum operations
1 x 10
7
1 x 10
5
at 20 A 230 VAC Res.
Mechanical
Electrical
Operate Time (typical)
15 ms at nominal coil voltage
Release Time (typical)
10 ms at nominal coil voltage
(with no coil suppression)
Dielectric Strength
(at sea level for 1 min.)
1000 Vrms between open contacts
2000 Vrms coil to contact
Insulation
Resistance
1000 megohms min. at 20°C, 500 VDC,
50% RH
Dropout
Greater than 10% of nominal coil voltage
Ambient Temperature
Operating
Storage
At nominal coil voltage
-40°C (-40°F) to 70°C (158°F)
-40°C (-40°F) to 105°C (221°F)
Vibration
0.062" (1.5 mm) DA at 10–55 Hz
Shock
Operating
Non-Operating
100 g, 11 ms,
1
/
2
sine (no damage)
20 g, 11 ms,
1
/
2
sine (no false operation)
Enclosure
P.B.T. polyester
Terminals
Tinned copper alloy
P.C. & quick connect
Note: Allow suitable slack on leads when wiring
and do not subject the terminals to excessive
force.
Max. Solder Temp.
270°C (518°F)
Max. Solder Time
5 seconds
Weight
40 grams
Packing unit in pcs
50 per plastic tray / 500 per carton box
ZETTLER
electronics GmbH
Puchheim,
D-82178
Junkersstrasse 3,
Fax +49 89 800 97 200 www.ZETTLERelectronics.com
office@ZETTLERelectronics.com
0
97
800
89
+49
Tel.
Germany
2004-08-11
AZ760
20 AMP MINIATURE
POWER RELAY
FEATURES
Low cost
20 Amp switching
60 Amp inrush current
Quick connect terminals
Flux tight construction
UL, CUR file E44211
COIL
Power
At Pickup Voltage
(typical)
Max. Continuous
Dissipation
Temperature Rise
441 mW
3.0 W at 20°C (68°F) ambient
35°C (63°F) at nominal coil voltage
Temperature
Max. 130°C (266°F)
NOT ES
1. All values at 20°C (68°F).
2. Relay may pull in with less than “Must Operate” value.
3. Specifications subject to change without notice.