ADVANCED PRODUCT INFORMATION - Rev 0.1
12/2002
3
AWS5522
ELECTRICAL CHARACTERISTICS
Table 3: Absolute Minimum and Maximum Ratings
Stresses in excess of the absolute ratings may cause permanent damage. Functional operation is not
implied under these conditions. Exposure to absolute ratings for extended periods of time may adversely
affect reliability.
Notes:
(1) The VS1 and VS2 ports may remain open-circuited without damage to the device.
(2) Storage Temperature limits apply to the die only after it has been removed from the ANADIGICS
shipping material. (The limits apply at all times for the packaged device.)
3. The RF1, RF2 and RFC ports should be AC-coupled. No external DC bias should be applied.
PARAMETER
Common Port Bias Voltage (V
S
)
Control Voltages (V
1
, V
2
)
RF Input Power (P
IN
)
Storage Temperature
(2)
MIN
-0.2
-0.2
-
-65
MAX
+8.0
+8.0
10
+150
UNIT
V
V
W
°
C
COMMENTS
at VS1 or VS2
(1)
at RF1,
RF2 and RFC
The device may be operated safely over these conditions; however, parametric performance is guaranteed only
over the conditions defined in the electrical specifications.
Notes:
(1) For optimal linearity performance, the Common Port Bias Voltage (V
S
) should be set to the same Control Voltage used
to turn ON either of the individual RF paths. The VS1 and VS2 ports may remain open-circuited without damage to the
device, but with some degradation in linearity.
Table 4: Operating Ranges
PARAMETER
RF Frequency (f)
Common Port Bias Voltage (V
S
)
Control Voltages (V
1
, V
2
)
Ambient Temperature (T
A
)
MIN
0.5
0
+2.5
-30
TYP
-
(1)
-
-
-
MAX
2.5
+0.2
+3.5
+85
UNIT
GHz
V
°
C
COMMENTS
applied at either VS1
or VS2 port
RF path OFF state
RF path ON state