4
Lucent Technologies Inc.
Data Sheet
November 1999
L7582 Tip Ring Access Switch
Electrical Characteristics
T
A
= –40
°
C to +85
°
C, unless otherwise specified.
Minimum and maximum values are testing requirements. Typical values are characteristics of the device and are
the result of engineering evaluations. Typical values are for information purposes only and are not part of the test-
ing requirements.
Table 4. Power Supply Specifications
* V
BAT
is used only as a reference for internal protection circuitry. If V
BAT
rises above –10 V, the device will enter an all OFF state and will remain
in the all OFF state until the battery voltage drops below –15 V.
Table 5. Break Switches, 1 and 2
* This parameter is not tested in production. Choice of secondary protector should ensure this rating is not exceeded.
Applied voltage is 100 Vp-p square wave at 100 Hz.
Supply
Min
4.5
–19
Typ
5
—
Max
5.5
–72
Unit
V
V
V
DD
V
BAT*
Parameter
Test Condition
Measure
Min
Typ
Max
Unit
OFF-state Leakage
Current:
+25
°
C
+85
°
C
–40
°
C
Vswitch (differential) = –320 V to Gnd
Vswitch (differential) = –60 V to +260 V
Vswitch (differential) = –330 V to Gnd
Vswitch (differential) = –60 V to +270 V
Vswitch (differential) = –310 V to Gnd
Vswitch (differential) = –60 V to +250 V
Iswitch
Iswitch
Iswitch
—
—
—
—
—
—
1
1
1
μ
A
μ
A
μ
A
ON-resistance
(SW1, SW2):
+25
°
C
+85
°
C
–40
°
C
ON-resistance Match
T
LINE
=
±
10 mA,
±
40 mA, T
BAT
= –2 V
T
LINE
=
±
10 mA,
±
40 mA, T
BAT
= –2 V
T
LINE
=
±
10 mA,
±
40 mA, T
BAT
= –2 V
Per ON-resistance test
condition of SW1, SW2
Iswitch = I
LIMIT
@ 50 Hz/60 Hz
V
ON
V
ON
V
ON
Magnitude
R
ON
SW1 – R
ON
SW2
V
ON
—
—
—
—
19.5
—
14.5
0.2
—
28
—
1.0
ON-state Voltage*
dc Current Limit:
+85
°
C
–40
°
C
Dynamic Current Limit
(t = < 0.5
μ
s)
—
—
220
V
Vswitch (on) =
±
10 V
Vswitch (on) =
±
10 V
Break switches in ON state; ringing
access switches off; apply
±
1000 V at
10/1000
μ
s pulse; appropriate second-
ary protection in place
Iswitch
Iswitch
Iswitch
80
—
—
—
—
2.5
—
250
—
mA
mA
A
Isolation:
+25
°
C
+85
°
C
–40
°
C
Vswitch (both poles) =
±
320 V,
Logic inputs = Gnd
Vswitch (both poles) =
±
330 V,
Logic inputs = Gnd
Vswitch (both poles) =
±
310 V,
Logic inputs = Gnd
—
Iswitch
Iswitch
Iswitch
—
—
—
—
—
—
1
1
1
μ
A
μ
A
μ
A
dV/dt Sensitivity
—
—
200
—
V/μs