![](http://datasheet.mmic.net.cn/340000/AS225-313_datasheet_16461923/AS225-313_3.png)
DATA SHEET AS225-313, AS225-313LF
Skyworks Solutions, Inc. Phone [781] 376-3000 Fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com
200148 Rev.A Skyworks Proprietary and Confidential Information Products and Product Information are Subject to Change Without Notice. February 15, 2005
3
C
BL
C
BL
V
1
J
1
V
2
J
2
GND
J
3
C
BL
3
2
1
6
5
4
Pin Out (Top View)
V
1
0
V
2
J
1
–J
2
Isolation
Insertion loss
J
1
–J
3
V
HIGH
0
Insertion loss
Isolation
V
HIGH
Truth Table
V
HIGH
= +2.5 to +5 V.
DC blocking capacitors (C
BL
) must be supplied externally.
C
BL
= 15 pF.
L
Frequency (GHz)
Insertion Loss vs. Frequency
-2.0
0
1
2
3
4
5
6
-1.8
-1.6
-1.4
-1.2
-0.8
-0.6
-0.4
-0.2
0
-1.0
J
1
–J
2
Path
J
1
–J
3
Path
I
Frequency (GHz)
Isolation vs. Frequency
-40
-35
-30
-25
-20
-15
-10
-5
0
J
1
–J
2
Path
J
1
–J
3
Path
0
1
2
3
4
5
6
R
Frequency (GHz)
Return Loss vs. Frequency
-45
-40
-35
-30
-25
-20
-15
-10
-5
0
J
1
–J
2
Path
J
1
–J
3
Path
0
1
2
3
4
5
6
Typical Performance Data (0, +3 V)
Characteristic
Value
Max input power @ 0/3 V
32 dBm
Max input power @ 0/5 V
35 dBm
Operating voltage
+8.0 V
Operating temperature
-40 °C to +85 °C
Storage temperature
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
-65 °C to +150 °C
Absolute Maximum Ratings
CAUTION:
Although this device is designed to be as robust as
possible, Electrostatic Discharge (ESD) can damage
this device.This device must be protected at all times
from ESD. Static charges may easily produce poten-
tials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.