AQW210HL
5/7/2001
4. Turn off time vs. ambient temperature char-
acteristics
LED current: 5 mA; Load voltage: Max.(DC);
Continuous load current: Max.(DC)
0.3
5. LED operate current vs. ambient tempera-
ture characteristics
Load voltage: Max.(DC);
Continuous load current: Max.(DC)
5
6. LED turn off current vs. ambient temperature
characteristics
Load voltage: Max.(DC);
Continuous load current: Max.(DC)
5
T
Ambient temperature,
°
C
0
0.05
0.1
0.15
0.2
–20
–40
0.25
0
20
40
60
80 85
L
Ambient temperature,
°
C
0
1
2
3
4
–20
–40
0
20
40
60
80 85
L
Ambient temperature,
°
C
0
1
2
3
4
–40
–20
0
20
40
60
8085
7. LED dropout voltage vs. ambient tempera-
ture characteristics
LED current: 5 to 50 mA
8. Voltage vs. current characteristics of output
at MOS portion
Measured portion: between terminals 5 and 6, 7 and 8;
Ambient temperature: 25
°
C
77
140
120
100
80
°
F
9. Off state leakage current
Measured portion: between terminals 5 and 6, 7 and 8;
Ambient temperature: 25
°
C
77
°
F
0
–40 –20
20
40
60
80 85
L
Ambient temperature,
°
C
1.5
1.4
1.3
1.2
1.1
1.0
0
50mA
30mA
10mA
5mA
5
3
1
–5
–3
60
40
20
–20
–40
–60
–80
–100
–120
–140
–2
–4
2
Voltage, V
4
–1
C
O
Load voltage, V
10
–3
10
–6
10
–9
10
–12
0
60
100
20
40
80
10. LED forward current vs. turn on time char-
acteristics
Measured portion: between terminals 5 and 6, 7 and 8;
Load voltage: Max.(DC); Continuous load current:
Max.(DC); Ambient temperature: 25
3
°
C
77
°
F
11. LED forward current vs. turn off time char-
acteristics
Measured portion: between terminals 5 and 6, 7 and 8;
Load voltage: Max.(DC); Continuous load current:
Max.(DC); Ambient temperature: 25
0.2
°
C
77
°
F
12. Applied voltage vs. output capacitance
characteristics
Measured portion: between terminals 5 and 6, 7 and 8;
Frequency: 1 MHz; Ambient temperature: 25
°
C
77
°
F
T
LED forward current, mA
0
0.5
1
1.5
2
2.5
10
20
30
40
50
60
T
LED forward current, mA
0
0.05
0.1
10
0
20
30
40
50
60
0.15
O
Applied voltage, V
0
50
40
30
20
10
10
20
30
40
50
0
What is current limit
When a load current reaches the speci-
fied output control current, a current limit
function works against the load current to
keep the current a constant value.
The current limit circuit built into the Pho-
toMOS relay thus controls the instanta-
neous load current to effectively ensure
circuit safety.
This safety feature protects circuits down-
stream of the PhotoMOS relay against
over-current.
But, if the current-limiting feature is used
longer than the specified time, the Photo-
MOS relay can be destroyed. Therefore,
set the output loss to the max. rate or less.
Comparison of output voltage and output
current characteristics
V-I Characteristics
O
Output voltage
All Rights Reserved, Copyright Matsushita Electric Works, Ltd.
Go To Online Catalog