5A Low Dropout Positive Adjustable or Fixed-Mode Regulator
Absolute Maximum Ratings
Symbol
Parameter
Vin
DC Supply Voltage
P
D
Power Dissipation
T
ST
Storage Temperature
T
OP
Operating Junction Temperature Range
Electrical Characteristics
(Under Operating Conditions)
SYM.
PARAMETER
CONDITIONS (Notes)
V
REF
Reference Voltage
Io=10mA, Tj=25
o
C, (Vin-Vout)=1.5V
AP1084-XXX
I
O
=10mA, V
OUT
+1.5V<V
IN
<12V, T
J
=25
o
C
AP1084-1.5
I
OUT
= 10mA, T
J
= 25
o
C, 3V
≦
V
IN
≦
12V
AP1084-1.8
I
OUT
= 10mA, T
J
= 25
o
C, 3.3V
≦
V
IN
≦
12V
AP1084-2.5
I
OUT
= 10mA, T
J
= 25
o
C, 4V
≦
V
IN
≦
12V
AP1084-3.3
I
OUT
= 10mA, T
J
= 25
o
C, 4.8V
≦
V
IN
≦
12V
AP1084-5.0
I
OUT
= 10mA, T
J
= 25
o
C, 6.5V
≦
V
IN
≦
12V
V
IN
=3.3V, 0mA<Io<5A, T
J
=25
o
C
(Note 1,2)
V
IN
=3V, 0mA<Io<5A, T
J
=25
o
C
(Note 1,2)
V
IN
=3.3V, 0mA<Io<5A
T
J
=25
C (Note 1,2)
V
IN
=4V, 0mA<Io<5A
T
J
=25
C (Note 1,2)
AP1084-3.3
V
IN
= 5V, 0mA<Io<5A , T
J
=25
o
C (Note 1,2)
AP1084-5.0
V
IN
= 8V, 0mA<Io<5A, T
J
=25
o
C (Note 1,2)
Vo
Dropout Voltage
Io=5.0A (
Vout = 1% Vout)
Current Limit
Vin-Vout=5V
Minimum Load
Current
Temperature Stability Io=10mA
Thermal Resistance
Junction-to-Ambient
(No heat sink ;No air
flow)
TO-252: Control Circuitry/Power Transistor
TO-263: Control Circuitry/Power Transistor
TO-220: Control Circuitry/Power Transistor
AP1084
Anachip Corp.
www.anachip.com.tw
Rev.1.0 Aug.27, 2004
3/10
Rating
-0.3 to 12
Unit
V
Internally Limited
-65 to +150
0 to +150
oC
oC
MIN
1.225
TYP
1.250
1.500
1.800
2.500
3.300
5.000
MAX
1.275
0.2
1.530
1.836
2.550
3.365
5.100
UNIT
V
%
V
V
V
V
V
1.470
1.764
2.450
3.235
4.900
Line
Regulation
AP1084-Adj
1
%
AP1084-1.5
12
15
mV
AP1084-1.8
15
18
mV
AP1084-2.5
20
25
mV
26
40
1.3
33
50
1.4
mV
mV
V
A
Load
Regulation
5.1
5
10
mA
0.5
%
θ
JA
TO-252
TO-263
TO-220
98
91
83
O
C/W
θ
JC
Thermal Resistance
Junction-to-Case
15
10
0.65/2.7
O
C/W
Note 1: See thermal regulation specifications for changes in output voltage due to heating effects. Line and load regulation are measured
at a constant junction temperature by low duty cycle pulse testing. Load regulation is measured at the output lead = 1/18” from the
package.
Note 2:Line and load regulation are guaranteed up to the maximum power dissipation of 15W. Power dissipation is determined by the
difference between input and output and the output current. Guaranteed maximum power dissipation will not be available over
the full input/output range.