Am29F017B
21
P R E L I M I N A R Y
ABSOLUTE MAXIMUM RATINGS
Storage Temperature
Plastic Packages . . . . . . . . . . . . . . .
–65
°
C to +125
°
C
Ambient Temperature
with Power Applied. . . . . . . . . . . . . . –55
°
C to +125
°
C
Voltage with Respect to Ground
V
CC
(Note 1) . . . . . . . . . . . . . . . . .–2.0 V to 7.0 V
A9, OE#, RESET# (Note 2). . . . .–2.0 V to 12.5 V
All other pins (Note 1) . . . . . . . . . .–2.0 V to 7.0 V
Output Short Circuit Current (Note 3) . . . . . . 200 mA
Notes:
1.
Minimum DC voltage on input or I/O pins is –0.5 V. During
voltage transitions, inputs may overshoot V
SS
to –2.0 V
for periods of up to 20 ns. See Figure 6. Maximum DC
voltage on output and I/O pins is V
CC
+ 0.5 V. During
voltage transitions, outputs may overshoot to V
CC
+ 2.0 V
for periods up to 20 ns. See Figure 7.
2. Minimum DC input voltage on A9, OE#, RESET# pins is
–0.5V During voltage transitions, A9, OE#, RESET# pins
may overshoot V
SS
to –2.0 V for periods of up to 20 ns.
See Figure 6. Maximum DC input voltage on A9, OE#,
and RESET# is 12.5 V which may overshoot to 13.5 V for
periods up to 20 ns.
3. No more than one output shorted at a time. Duration of
the short circuit should not be greater than one second.
Stresses greater than those listed in this section may cause
permanent damage to the device. This is a stress rating
only; functional operation of the device at these or any other
conditions above those indicated in the operational sections
of this specification is not implied. Exposure of the device to
absolute maximum rating conditions for extended periods
may affect device reliability.
Figure 6.
Maximum Negative Overshoot
Waveform
Figure 7.
Maximum Positive Overshoot
Waveform
OPERATING RANGES
Commercial (C) Devices
Case Temperature (T
C
) . . . . . . . . . . . . . 0
°
C to +70
°
C
Industrial (I) Devices
Case Temperature (T
C
) . . . . . . . . . . .
–40
°
C to +85
°
C
Extended (E) Devices
Ambient Temperature (T
A
) . . . . . . . . –55°C to +125°C
V
CC
Supply Voltages
V
CC
for± all devices . . . . . . . . . . . . . .+4.5 V to +5.5 V
Operating ranges define those limits between which the
functionality of the device is guaranteed.
20 ns
20 ns
+0.8 V
–0.5 V
20 ns
–2.0 V
21195B-10
20 ns
20 ns
V
CC
+2.0 V
V
CC
+0.5 V
20 ns
2.0 V
21195B-11