ADS7803
6
STARTING A CONVERSION
A conversion is initiated on the rising edge of the WR input,
with valid signals on A0, A1 and CS. The selected input
channel is sampled for five clock cycles. The successive
approximation conversion takes place during clock cycles 6
through 17.
Figures 2 and 3 show the full conversion sequence and the
timing to initiate a conversion.
A conversion can also be initiated by a rising edge on pin 26,
if a HIGH has been written to D2 of the Special Function
Register, as discussed below.
CALIBRATION
A calibration cycle is initiated automatically upon power-up
(or after a power failure). Calibration can also be initiated by
the user at any time by the rising edge of a minimum 100ns-
wide LOW pulse on the CAL pin (pin 26), or by setting D1
HIGH in the Special Function Register (see SFR section).
A calibration command will initiate a calibration cycle,
regardless of whether a conversion is in process. During a
calibration cycle, convert commands are ignored.
Calibration takes 168 clock cycles, and a normal conversion
(17 clock cycles) is added automatically. Thus, at the end of
a calibration cycle, there is valid conversion data in the
output registers. For maximum accuracy, the supplies and
reference need to be stable during the calibration procedure.
To ensure that supply voltages have settled and are stable, an
internal timer provides a waiting period of 42,425 clock
cycles between power-up/power-failure and the start of the
calibration cycle.
PIN #
NAME
DESCRIPTION
1
SFR
Special Function Register. When connected to a microprocessor address pin, allows access to special functions
through D0 to D7. See the sections discussing the Special Function Register. If not used, connect to DGND. This pin
has an internal pull-down.
2 to 5
AIN0 to AIN3
Analog inputs. Channel 0 to channel 3.
6
V
REF
+
Positive voltage reference input. Normally +5V. Must be
≤
V
A
.
7
V
REF
–
Negative voltage reference input. Normally 0V.
8
DGND
Digital ground. DGND = 0V.
9
V
D
Logic supply voltage. V
D
= +5V. Must be
≤
V
A
and applied after V
A
.
10 to 17
D0 to D7
Data Bus Input/Output Pins. Normally used to read output data. See section on SFR (Special Function Register) for
other uses.
When SFR is LOW, these function as follows:
Data Bit 7 if HBE is LOW; if HBE is HIGH, acts as converter status pin and is HIGH during conversion or calibration,
goes LOW after the conversion is completed. (Acts as an inverted BUSY).
Data Bit 6 if HBE is LOW; LOW if HBE is HIGH.
Data Bit 5 if HBE is LOW; LOW if HBE is HIGH.
Data Bit 4 if HBE is LOW; LOW if HBE is HIGH.
Data Bit 3 if HBE is LOW; Data Bit 11 (MSB) if HBE is HIGH.
Data Bit 2 if HBE is LOW; Data Bit 10 if HBE is HIGH.
Data Bit 1 if HBE is LOW; Data Bit 9 if HBE is HIGH.
Data Bit 0 (LSB) if HBE is LOW; Data Bit 8 if HBE is HIGH.
10
D7
11
12
13
14
15
16
17
D6
D5
D4
D3
D2
D1
D0
18
RD
Read Input. Active LOW; used to read the data outputs in combination with CS and HBE.
19
CS
Chip Select Input. Active LOW.
20
WR
Write Input. Active LOW; used to start a new conversion and to select an analog channel via address inputs A0 and A1
in combination with CS. The minimum WR pulse LOW width is 100ns.
21
HBE
High Byte Enable. Used to select high or low data output byte in combination with CS and RD, or to select SFR.
22
BUSY
BUSY is LOW during conversion or calibration. BUSY goes HIGH after the conversion is completed.
23
CLK
Clock Input. For internal or external clock operation. For external clock operation, connect pin 23 to a 74HC-compatible
clock source. For internal clock operation, connect pin 23 per the clock operation description.
24 to 25
A0 to A1
Address Inputs. Used to select one of four analog input channels in combination with CS and WR. The address inputs
are latched on the rising edge of WR or CS.
A1
A0
Selected Channel
LOW
LOW
HIGH
HIGH
LOW
HIGH
LOW
HIGH
AIN0
AIN1
AIN2
AIN3
26
CAL
(SHC)
Calibration Input. A calibration cycle is initiated when CAL is LOW. The minimum pulse width of CAL is 100ns. If not
used, connect to V
D
. In this case calibration is only initiated at power on, or with SFR. If D2 of the SFR is programmed
HIGH, pin 26 will be used as an input to control the sample-to-hold timing. A rising edge on pin 26 will switch from
sample-mode to hold-mode and initiate a conversion. This pin has an internal pull-up.
27
AGND
Analog Ground. AGND = 0V.
28
V
A
Analog Supply. V
A
= +5V. Must be
≥
V
D
and V
REF
+.
PIN ASSIGNMENTS