PIN DE SCRIPT ION
Pin
1
2
3
4
Function
C
P
+, Pump Capacitor Positive Input.
Ground.
C
P
–, Pump Capacitor Negative Input.
Shutdown, Logic Level Shutdown Pin. Application of a
logic low to this pin will place the regulator in normal
operation. T he device will be put into shutdown mode
with the shutdown pin pulled to V
IN
. In Shutdown
mode the charge pump is turned off. Connect to ground
for normal operation.
V
SENSE
, Output Voltage Sense Line. T his is used to im-
prove load regulation performance by eliminating IR
drop on the output traces. See application section for
more detail. For normal operation, connect Pin 5 to
V
OUT
(Pin 7).
NC, No Internal Electrical Connection.
V
OUT ,
Output Pin. Regulated negative output voltage.
Connect a low ESR capacitor between this pin and de-
vice GND.
V
IN,
Positive Supply Input when 4.5 V
≤
V
IN
≤
6 V.
Connect a low-ESR bypass capacitor between this pin
and the device ground pin.
5
6
7
8
Parameter
OPERAT ING SUPPLY RANGE
Symbol
V
S
Condition
Min
4.5
T yp
5
Max
6
Units
V
SUPPLY CURRENT
I
S
2.9
3
1.5
1.6
3.5
4
2.5
3.0
mA
mA
mA
mA
–40
°
C < T
A
< +85
°
C
Shutdown Mode
–40
°
C < T
A
< +85
°
C
OUT PUT
Output Voltage
V
O
V
O
V
O
I
O
= 60 mA
I
O
= 10 mA to 120 mA, 4.5 V < V
IN
< 6 V
I
O
= 10 mA to 120 mA, 4.5 V < V
IN
< 6 V,
0
°
C < T
A
< +70
°
C
I
O
= 10 mA to 120 mA, 4.5 V < V
IN
< 6 V,
–40
°
C < T
A
< +85
°
C
I
O
= 10 mA–60 mA
I
O
= 10 mA–120 mA
–3.1
–3.1
–3.0
–3
–2.91
–2.88
V
V
–3.12
–3
–2.85
V
V
O
–3.2
–3
0.9
1.5
8
25
55
–2.8
V
mV/mA
mV/mA
mV
mV
Load Regulation
V
O
/ I
O
Output Resistance
2
Output Ripple Voltage
3
R
O
V
RIPPLE
C1–C3 = 10
μ
F, I
LOAD
= 80 mA
C1–C3 = 10
μ
F,
I
LOAD
= 120 mA
SWIT CHING FREQUENCY
F
S
100
96
120
120
135
140
kHz
kHz
–40
°
C < T
A
< +85
°
C
SHUT DOWN
Logic Input High
Input Current
Logic Input Low
Input Current
T urn-On-T ime
T urn-Off-T ime
V
IH
I
IH
V
IL
I
IL
t
ON
t
OFF
2.4
V
μ
A
V
μ
A
ms
ms
1
0.4
1
5
5
Figure 1, I
L
= 120 mA
Figure 1, I
L
= 120 mA
NOT ES
1
Capacitors C1 and C2 used in the test circuit are 10
μ
F with 0.1
ESR. Capacitors with higher ESR may reduce output voltage and efficiency.
2
Open-loop output resistance.
3
See Figure 1 conditions.
All limits at temperature extremes are guaranteed via correlation using standard Statistical Quality Control (SQC) methods.
Specifications subject to change without notice
.
REV. 0
–2–
ADP3604–SPECIFICATIONS
WARNING!
ESD SENSITIVE DEVICE
C AUT ION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the ADP3604 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. T herefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
(V
IN
= 5.0 V @ T
A
= +25
8
C, C
P
= C
OUT
= 10
m
F unless otherwse noted)
ABSOLUT E MAX IMUM RAT INGS
1
(T
A
= +25
°
C unless otherwise noted)
Input Voltage (V+ to GND, GND to OUT ) . . . . . . . . . +7.5 V
Output Short Circuit Protection . . . . . . . . . . . . . . . . . . . .1 sec
Power Dissipation, SO-8 . . . . . . . . . . . . . . . . . . . . . . .660 mW
θ
JA2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
°
C/W
θ
JC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
°
C/W
Operating T emperature Range . . . . . . . . . . . . .–40
°
C to +85
°
C
Storage T emperature Range . . . . . . . . . . . . .–65
°
C to +150
°
C
Lead T emperature Range (Soldering 10 sec) . . . . . . . . +300
°
C
Vapor Phase (60 sec) . . . . . . . . . . . . . . . . . . . . . . . . +215
°
C
Infrared (15 sec) . . . . . . . . . . . . . . . . . . . . . . . . . . . . +220
°
C
NOT ES
1
T his is a stress rating only and functional operation of the device at these or any
other conditions above those indicated in the operation section of this specification
is not implied. Exposure to absolute maximum rating conditions for extended
periods may affect device reliability.
2
θ
JA
is specified for worst case conditions with device soldered on a circuit board.
ORDE RING GUIDE
Model
ADP3604AR
*SO = Small Outline Package.
T emperature Range
–40
°
C to +85
°
C
Package Option*
SO-8