Layout Considerations
Digital boards can be electrically noisy environments, and
the ADM1032 is measuring very small voltages from the
remote sensor, so care must be taken to minimize noise
induced at the sensor inputs. The following precautions
should be taken.
1. Place the ADM1032 as close as possible to the
remote sensing diode. Provided that the worst
noise sources, that is, clock generators,
data/address buses, and CRTs, are avoided, this
distance can be four to eight inches.
2. Route the D+ and D tracks close together, in
parallel, with grounded guard tracks on each side.
Provide a ground plane under the tracks if
possible.
3. Use wide tracks to minimize inductance and
reduce noise pickup. 10 mil track minimum width
and spacing is recommended.
Figure 18. Typical Arrangement of Signal Tracks
10 MIL
10 MIL
10 MIL
10 MIL
10 MIL
10 MIL
10 MIL
GND
D
D+
GND
4. Try to minimize the number of copper/solder
joints, which can cause thermocouple effects.
Where copper/solder joints are used, make sure
that they are in both the D+ and D path and at the
same temperature.
Thermocouple effects should not be a major
problem since 1癈 corresponds to about 200 mV
and thermocouple voltages are about 3 mV/癈 of
temperature difference. Unless there are two
thermocouples with a big temperature differential
between them, thermocouple voltages should be
much less than 200 mV.
5. Place a 0.1 mF bypass capacitor close to the V
DD
pin. In very noisy environments, place a 1000 pF
input filter capacitor across D+ and D close to the
ADM1032.
6. If the distance to the remote sensor is more than
eight inches, the use of twisted pair cable is
recommended. This works up to about 6 feet to
12 feet.
7. For really long distances (up to 100 feet), use
shielded twisted pair, such as Belden #8451
microphone cable. Connect the twisted pair to D+
and D and the shield to GND close to the
ADM1032. Leave the remote end of the shield
unconnected to avoid ground loops.
Because the measurement technique uses switched
current sources, excessive cable and/or filter capacitance
can affect the measurement. When using long cables, the
filter capacitor can be reduced or removed.
Cable resistance can also introduce errors. 1 W series
resistance introduces about 1癈 error.
Power Sequencing Considerations
Power Supply Slew Rate
When powering up the ADM1032 you must ensure that
the slew rate of V
DD
 is less than 18 mV/ms. A slew rate larger
than this may cause power-on-reset issues and yield
unpredictable results.
THERM
 Pin Pullup
As mentioned above, the THERM
 signal is open drain and
requires a pullup to V
DD
. The THERM
 signal must always
be pulled up to the same power supply as the ADM1032,
unlike the SMBus signals (SDA, SCL and ALERT
) that can
be pulled to a different power rail. The only time the
THERM
 pin can be pulled to a different supply rail (other
than V
DD
) is if the other supply is powered up simultaneous
with, or after the ADM1032 main V
DD
. This is to protect the
internal circuitry of the ADM1032. If the THERM
 pullup
supply rail were to rise before V
DD
, the POR circuitry may
not operate correctly.
Application Circuit
Figure 19 shows a typical application circuit for the
ADM1032, using a discrete sensor transistor connected via
a shielded, twisted pair cable. The pullups on SCLK,
SDATA, and ALERT
  are required only if they are not
already provided elsewhere in the system.
The SCLK and SDATA pins of the ADM1032 can be
interfaced directly to the SMBus of an I/O controller, such
as the Intel 820 chipset.
相關(guān)PDF資料
PDF描述
ADM1033ARQZ-RL7 IC THERM/FAN SPEED CTLR 16-QSOP
ADM1034ARQZ-REEL IC THERM/FAN SPEED CTRLR 16-QSOP
ADN8810ACPZ-REEL7 IC CURRENT SOURCE(12BIT) 24LFCSP
ADP2140ACPZ3328R7 IC REG DL BCK/LINEAR 10LFCSP
ADP5022ACBZ-6-R7 IC REG TRPL BCK/LINEAR 16WLCSP
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
ADM1032ARZ-REEL7 功能描述:板上安裝溫度傳感器 8-PIN TDM RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準(zhǔn)確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關(guān)閉: 安裝風(fēng)格: 封裝 / 箱體: 設(shè)備功能:Temperature and Humidity Sensor
ADM1033 制造商:ONSEMI 制造商全稱:ON Semiconductor 功能描述:Thermal Monitor and Fan Speed (RPM) Controller
ADM1033ARQ 功能描述:IC THERM/FAN SPEED CTRLR 16-QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標(biāo)準(zhǔn)包裝:1 系列:- 功能:溫度監(jiān)控系統(tǒng)(傳感器) 傳感器類型:內(nèi)部和外部 感應(yīng)溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠(yuǎn)程(最大值) 拓?fù)?ADC,比較器,寄存器庫(kù) 輸出類型:2 線 SMBus? 輸出警報(bào):無(wú) 輸出風(fēng)扇:無(wú) 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應(yīng)商設(shè)備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1033ARQ-REEL 功能描述:IC THERM/FAN SPEED CTRLR 16-QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標(biāo)準(zhǔn)包裝:1 系列:- 功能:溫度監(jiān)控系統(tǒng)(傳感器) 傳感器類型:內(nèi)部和外部 感應(yīng)溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠(yuǎn)程(最大值) 拓?fù)?ADC,比較器,寄存器庫(kù) 輸出類型:2 線 SMBus? 輸出警報(bào):無(wú) 輸出風(fēng)扇:無(wú) 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應(yīng)商設(shè)備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1033ARQ-REEL7 功能描述:IC THERM/FAN SPEED CTRLR 16-QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標(biāo)準(zhǔn)包裝:1 系列:- 功能:溫度監(jiān)控系統(tǒng)(傳感器) 傳感器類型:內(nèi)部和外部 感應(yīng)溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠(yuǎn)程(最大值) 拓?fù)?ADC,比較器,寄存器庫(kù) 輸出類型:2 線 SMBus? 輸出警報(bào):無(wú) 輸出風(fēng)扇:無(wú) 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應(yīng)商設(shè)備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6