![](http://datasheet.mmic.net.cn/Analog-Devices-Inc/ADG804YRM_datasheet_96174/ADG804YRM_6.png)
ADG804
Data Sheet
Rev. A | Page 6 of 16
ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Table 4.
Parameter
Rating
VDD to GND
0.3 V to +4.6 V
0.3 V to VDD + 0.3 V
0.3 V to +4.6 V or 10 mA,
whichever occurs first
Peak Current, S or D
(Pulsed at 1 ms, 10% Duty
Cycle Max)
3.3 V Operation
500 mA
2.5 V Operation
460 mA
1.8 V Operation
420 mA
Continuous Current, S or D
3.3 V Operation
300 mA
2.5 V Operation
275 mA
1.8 V Operation
250 mA
Operating Temperature Range
Automotive (Y Version)
40°C to +125°C
Storage Temperature Range
65°C to +150°C
Junction Temperature
150°C
MSOP Package
θJA Thermal Impedance
206°C/W
θJC Thermal Impedance
44°C/W
Lead Temperature, Soldering
As per JEDEC J-STD-020
1
Overvoltages at IN, S, or D are clamped by internal diodes. Current should be
limited to the maximum ratings given.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those listed in the operational sections
of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability. Only one absolute maximum rating may be
applied at any one time.
Table 5. ADG804 Truth Table
A1
A0
EN
ON Switch
x
0
None
0
1
S1
0
1
S2
1
0
1
S3
1
S4
ESD CAUTION