PRELIMINARY
TECHNICAL
V
I
O
= 25 A
ADDC27008PB–SPECIFICATIONS
ELECTRICAL CHARACTERISTICS
–55
8
C to +90
8
C; all temperatures are case and T
C
is the temperature measured at the center of the package bottom)
Case
T emp
T est
Level
ADDC27008PB
T yp
Parameter
Conditions
Min
Max
Units
INPUT CHARACT ERIST ICS
Steady State Operating Input Voltage Range
1
Abnormal Operating Input Voltage Range
(Per MIL-ST D-704D)
1
No Load Input Current
Disabled Input Current
Full
VI
I
O
= 1.25 A to 25 A Pulsed
180
270
350
V
Full
+25
°
C
+25
°
C
VI
VI
VI
I
O
= 1.25 A to 20 A Pulsed
160
440
100
5
V
mA
mA
45
1
OUT PUT CHARACT ERIST ICS
2, 3
Output Voltage (V
O
)
+25
°
C
Full
Full
+25
°
C
+25
°
C
Full
+25
°
C
+25
°
C
+25
°
C
I
VI
VI
VI
VI
VI
V
V
I
O
= 1.25 A to 25 A, V
IN
= 180 V to 350 V dc
I
O
= 1.25 A to 25 A, V
IN
= 180 V to 350 V dc
I
O
= 1.25 A to 20 A, V
= 160 V to 440 V dc
I
O
= 25 A Pulsed, V
= 180 V to 350 V dc
V
IN
= 270 V dc, I
O
= 1.25 A to 25 A Pulsed
V
= 180 V to 350 V dc, Pulsed
O
= 25 A, Open Remote Sense Connection
V
O
= 90% V
OUT
Nom
45 m
≤
R
SHORT
Circuit
≤
60 m
7.92
7.84
7.84
8.00
8.08
8.16
8.16
5
10
60
25
V
V
V
mV
mV
mV p-p
A
% V
O
nom
% I
O
max
A
Line Regulation
Load Regulation
Output Ripple/Noise
4
Output Current (I
)
5
Output Overvoltage Protection
Output Current Limit
Output Short Circuit Current
1
2.5
40
1.25
120
130
40
ISOLAT ION CHARACT ERIST ICS
Isolation Resistance
+25
°
C
Input to Output or Any Pin to Case at 500 V dc
100
M
DYNAMIC CHARACT ERIST ICS
4
Step Changes In Load (min to max)
Step Changes In Load (max to min)
+25
°
C
I
(Reference Section Entitled “T ransient Response”)
(Reference Section Entitled “Response at End
of Pulse”)
I
O
= 25 A, From Inhibit High to Status High
Soft Start T urn-On T ime
+25
°
C
I
6
10
ms
T HERMAL CHARACT ERIST ICS
Efficiency
+25
°
C
Full
+25
°
C
Full
+90
°
C
I
VI
I
VI
I
O
= 12.5 A
I
O
= 12.5 A
I
O
= 25 A
I
O
= 25 A
78
78
74
72.5
79
%
%
%
%
°
C
75
Hottest Junction T emperature
5
110
CONT ROL CHARACT ERIST ICS
Clock Frequency
ADJUST (Pin 3) V ADJ
ST AT US (Pin 4)
V
OH
V
OL
V
AUX
(Pin 5)
V
O
(nom)
INHIBIT (Pin 6)
V
IL
I
IL
V
I
(Open Circuit)
SYNC (Pin 7)
V
IH
I
IH
I
SHARE
(Pin 8)
T EMP (Pin 9)
Full
+25
°
C
VI
I
I
O
= 2 A
0.85
3.1
0.99
3.3
MHz
V
3.2
+25
°
C
+25
°
C
I
I
I
OH
= 400
μ
A
I
OL
= 1 mA
2.4
4.0
0.15
V
V
0.7
+25
°
C
I
I
AUX
= 5 mA, Load Current = 12.5 A
14.9
15.15
15.4
V
+25
°
C
+25
°
C
+25
°
C
I
I
I
0.5
1.2
15
V
mA
V
V
IL
= 0.5 V
+25
°
C
+25
°
C
+25
°
C
+25
°
C
I
I
I
V
4.0
V
μ
A
V
V
V
IH
= 7.0 V
I
O
= 20 A
150
2.65
2.45
2.55
3.90
NOTES
1
440 V dc upper limit rated for transient condition of up to 50 ms. 160 V dc lower limit rated for continuous operation during emergency condition. Steady state and
abnormal input voltage range require source impedance sufficient to insure input stability at low line. See sections entitled System Instability Considerations and Input
Voltage Range.
2
Measured at the remote sense points.
3
T ests performed at low continuous load and 200 W pulsed load. Unit does not regulate to zero load. Refer to section entitled Internal “Start-Up Circut”.
4
C
= 1,000
μ
F. Output ripple/noise measured at converter output; may be smaller at external load capacitance. Unit is stable for C
LOAD
ranging from 500
μ
F
to 4,000
μ
F.
5
Refer to section entitled “Pulse Output Power vs. Pulse Length” for more information.
6
Unit has internal pull-down; refer to section entitled Pin 7 (SYNC).
Specifications subject to change without notice.
REV. 0
–2–
(T
C
= +25
8
C, V
IN
= 270 V dc
6
0.5 V dc, unless otherwse noted; full temperature range is