參數(shù)資料
型號: AD7946BCPWP
廠商: ANALOG DEVICES INC
元件分類: ADC
英文描述: 14-Bit, 500 kSPS PulSAR⑩ ADC in MSOP/QFN
中文描述: 1-CH 14-BIT SUCCESSIVE APPROXIMATION ADC, SERIAL ACCESS, PDSO10
封裝: 3 X 3 MM, QFN-10
文件頁數(shù): 16/27頁
文件大小: 301K
代理商: AD7946BCPWP
Preliminary Technical Data
AD7946
Rev Pr D | Page 23 of 27
Chain Mode with BUSY Indicator
This mode can also be used to daisy chain multiple AD7946s on
a 3-wire serial interface while providing a BUSY indicator. This
feature is useful for reducing component count and wiring
connections, e.g., in isolated multiconverter applications or for
systems with a limited interfacing capacity. Data readback is
analogous to clocking a shift register.
A connection diagram example using three AD7946s is shown
in Figure 39 and the corresponding timing is given in Figure 40.
When SDI and CNV are low, SDO is driven low. With SCK
high, a rising edge on CNV initiates a conversion, selects the
chain mode, and enables the BUSY indicator feature. In this
mode, CNV is held high during the conversion phase and the
subsequent data readback. When all ADCs in the chain have
completed their conversions, the nearend ADC ( ADC C in
Figure 39) SDO will be driven high. This transition on SDO can
be used as a BUSY indicator to trigger the data readback
controlled by the digital host. The AD7946 then enters the
acquisition phase and powers down. The data bits stored in the
internal shift register are then clocked out, MSB first, by
subsequent SCK falling edges. For each ADC, SDI feeds the
input of the internal shift register and is clocked by the SCK
falling edge. Each ADC in the chain outputs its data MSB first,
and 14 × N + 1 clocks are required to readback the N ADCs.
Although the rising edge can be used to capture the data, a
digital host also using the SCK falling edge will allow a faster
reading rate and, consequently more AD7946s in the chain,
provided the digital host has an acceptable hold time. For
instance, with a 5 ns digital host set-up time and 3 V interface,
up to five AD7946s running at a conversion rate of 333 kSPS
can be daisy-chained to a single 3-wire port.
CNV
SCK
SDO
SDI
CLK
CONVERT
DATA IN
IRQ
DIGITAL HOST
AD7946
C
CNV
SCK
SDO
SDI
AD7946
B
CNV
SCK
SDO
SDI
AD7946
A
Figure 39. Chain Mode with BUSY Indicator Connection Diagram
04656-P
rC-018
SDOA = SDIB
DA13 DA12 DA11
SCK
12
3
35
41
42
tEN
CONVERSION
ACQUISITION
tCONV
tCYC
tACQ
ACQUISITION
CNV = SDIA
DA1
413
tSCK
tSCKH
tSCKL
DA0
15
31
13
SDOB = SDIC
DB13 DB12 DB11
DA1
DB1DB0DA13 DA12
43
tSSDISCK
tHSDISC
tHSDO
tDSDO
SDOC
DC13 DC12 DC11
DA1DA0
DC1DC0DA12
17
27
28
16
29
DB1DB0DA13
DB13 DB12
tDSDOSDI
tSSCKCNV
tHSCKCNV
DA0
Figure 40. Chain Mode with BUSY Indicator Serial Interface Timing
相關(guān)PDF資料
PDF描述
AD7942BCPWP 14-Bit, 250 kSPS PulSAR ADC in MSOP/QFN
AD574AJE Complete 12-Bit A/D Converter
AD574AJN Complete 12-Bit A/D Converter
AD574AKD Complete 12-Bit A/D Converter
AD574AKE Complete 12-Bit A/D Converter
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
AD7946BCPZRL 功能描述:IC ADC 14BIT 500KSPS 10-LFCSP RoHS:是 類別:集成電路 (IC) >> 數(shù)據(jù)采集 - 模數(shù)轉(zhuǎn)換器 系列:PulSAR® 標(biāo)準(zhǔn)包裝:1,000 系列:- 位數(shù):12 采樣率(每秒):300k 數(shù)據(jù)接口:并聯(lián) 轉(zhuǎn)換器數(shù)目:1 功率耗散(最大):75mW 電壓電源:單電源 工作溫度:0°C ~ 70°C 安裝類型:表面貼裝 封裝/外殼:24-SOIC(0.295",7.50mm 寬) 供應(yīng)商設(shè)備封裝:24-SOIC 包裝:帶卷 (TR) 輸入數(shù)目和類型:1 個(gè)單端,單極;1 個(gè)單端,雙極
AD7946BCPZRL7 功能描述:IC ADC 14BIT 500KSPS 10-LFCSP RoHS:是 類別:集成電路 (IC) >> 數(shù)據(jù)采集 - 模數(shù)轉(zhuǎn)換器 系列:PulSAR® 標(biāo)準(zhǔn)包裝:1,000 系列:- 位數(shù):12 采樣率(每秒):300k 數(shù)據(jù)接口:并聯(lián) 轉(zhuǎn)換器數(shù)目:1 功率耗散(最大):75mW 電壓電源:單電源 工作溫度:0°C ~ 70°C 安裝類型:表面貼裝 封裝/外殼:24-SOIC(0.295",7.50mm 寬) 供應(yīng)商設(shè)備封裝:24-SOIC 包裝:帶卷 (TR) 輸入數(shù)目和類型:1 個(gè)單端,單極;1 個(gè)單端,雙極
AD7946BRM 制造商:Analog Devices 功能描述: 制造商:Rochester Electronics LLC 功能描述:
AD7946BRMRL7 制造商:AD 制造商全稱:Analog Devices 功能描述:14-Bit, 500 kSPS PulSAR⑩ ADC in MSOP/QFN
AD7946BRM-RL7 制造商:Analog Devices 功能描述:ADC Single SAR 500ksps 14-bit Serial 10-Pin MSOP T/R