AD7680
Rev. A | Page 5 of 24
Parameter
A Version1
B Version1
Unit
Test Conditions/Comments
POWER REQUIREMENTS
VDD
2.5/4.096
V min/max
IDD
Digital I/Ps = 0 V or VDD
Normal Mode (Static)
2.8
mA max
SCLK on or off; VDD = 4.096 V
2
mA max
SCLK on or off; VDD = 3.6 V
Normal Mode (Operational)
2.6
mA max
fSAMPLE = 100 kSPS; VDD = 4.096 V; 1.75 mA typ
1.9
mA max
fSAMPLE = 100 kSPS; VDD = 3.6 V; 1.29 mA typ
Full Power-Down Mode
0.3
μA max
SCLK on or off
Normal Mode (Operational)
10.65
mW max
fSAMPLE = 100 kSPS; VDD = 4.096 V
6.84
mW max
fSAMPLE = 100 kSPS; VDD = 3.6 V
3
mW typ
VDD = 2.5 V
Full Power-Down
1.23
μW max
VDD = 4.096V
1.08
μW max
VDD = 3.6 V
1 Temperature range as follows: A, B Versions: 40°C to +85°C.
2 See the Terminology section.
3 Sample tested during initial release to ensure compliance.
4 See the Power vs. Throughput Rate section.