–3–
REV. 0
AD6630
Test
Level
Parameter
HIGH LEVEL CLAMP MAXIMUM OUTPUT @ 250 MHz
4, 5
PHASE VARIATION
6
Temp
Min
Typ
Max
Units
Full
+25
°
C
+25
°
C
+25
°
C
IV
11.2
12.2
dBm
V
9
Degree
CMRR
7
PSRR
8
V
50
dB
V
30
dB
NOTES
1
All specifications are valid across the operating frequency range when the source and load impedance are a conjugate match to the amplifier’s input and output
impedance.
2
Test is for two tones separated by 1 MHz for IFs at 70 MHz and 250 MHz at –23 dBm per tone input.
3
Low Level Clamp is selected by connecting pin CLLO to the negative supply, while pin CLHI is left floating. Clamping can be set at lower levels by connecting pin
CLLO and CLHI to the negative supply through an external resistor.
4
High Level Clamp is selected by connecting pin CLHI to the negative supply, while pin CLLO is left floating, this allows the maximum linear range of the device to
be utilized.
5
Output clamp levels are measured for hard clamping with a +3 dBm input level. Valid for a maximum input level of +8 dBm/200
= 3.2 V p-p—differential.
6
Measured as the change in output phase when the input level is changed from –53 dBm to +8 dBm (i.e., from linear operation to clamping).
7
Ratio of the differential output signal (referenced to the input) to the common-mode input signal presented to all input pins.
8
Ratio of signal on supply to differential output (<500 kHz).
Specifications subject to change without notice.
ABSOLUTE MAXIMUM RATINGS
Parameter
Min
Max
Units
Single Supply Voltage
Positive Supply Voltage
Negative Supply Voltage
Input Power
Storage Temperature
Junction Temperature
ESD Protection
–0.5
–0.5
–5.75
11.5
5.75
0.5
+8
+150
+150
V
V
V
dBm
°
C
°
C
kV
–65
1
EXPLANATION OF TEST LEVELS
I.
100% production tested.
II.
100% production tested at +25
°
C, and guaranteed by
design and analysis at temperature extremes.
III. Sample tested only.
IV. Parameter guaranteed by design and analysis.
V.
Parameter is typical value only.
VI. 100% production tested at +25
°
C, and sample tested at
temperature extremes.
ORDERING GUIDE
Model
Temperature Range
–40
°
C to +85
°
C (Ambient)
–40
°
C to +85
°
C (Ambient)
Package Description
Package Option
AD6630AR
AD6630AR-REEL
AD6630R/PCB
16-Lead Wide Body SOIC
AD6630AR on 1000 PC Reel
Evaluation Board with AD6630AR
R-16
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD6630 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE