AD5243/AD5248
Data Sheet
Rev. B | Page 4 of 20
ELECTRICAL CHARACTERISTICS: 10 k, 50 k, AND 100 k VERSIONS
VDD = 5 V ± 10%, or 3 V ± 10%; VA = VDD; VB = 0 V; 40°C < TA < 125°C; unless otherwise noted.
Table 2.
Parameter
Symbol
Conditions
Min
Max
Unit
DC CHARACTERISTICS—RHEOSTAT MODE
Resistor Differential Nonlinearit
y2R-DNL
RWB, VA = no connect
1
±0.1
+1
LSB
Resistor Integral Nonlinearit
y2R-INL
RWB, VA = no connect
2.5
±0.25
+2.5
LSB
Nominal Resistor Toleranc
e3RAB
TA = 25°C
20
+20
%
Resistance Temperature Coefficient
(RAB/RAB )/T
VAB = VDD, wiper = no connect
35
ppm/°C
Wiper Resistance
RWB
Code = 0x00, VDD = 5 V
160
200
DC CHARACTERISTICS—POTENTIOMETER
Differential Nonlinearit
y5DNL
1
±0.1
+1
LSB
INL
1
±0.3
+1
LSB
Voltage Divider Temperature Coefficient
(VW/VW)/T
Code = 0x80
15
ppm/°C
Full-Scale Error
VWFSE
Code = 0xFF
2.5
1
0
LSB
Zero-Scale Error
VWZSE
Code = 0x00
0
1
2.5
LSB
RESISTOR TERMINALS
VA, VB, VW
GND
VDD
V
CA, CB
f = 1 MHz, measured to GND,
code = 0x80
45
pF
CW
f = 1 MHz, measured to GND,
code = 0x80
60
pF
IA_SD
VDD = 5.5 V
0.01
1
A
Common-Mode Leakage
ICM
VA = VB = VDD/2
1
nA
DIGITAL INPUTS AND OUTPUTS
Input Logic High
VIH
VDD = 5 V
2.4
V
Input Logic Low
VIL
VDD = 5 V
0.8
V
Input Logic High
VIH
VDD = 3 V
2.1
V
Input Logic Low
VIL
VDD = 3 V
0.6
V
Input Current
IIL
VIN = 0 V or 5 V
±1
A
Input Capacitance
CIL
5
pF
POWER SUPPLIES
Power Supply Range
VDDRANGE
2.7
5.5
V
Supply Current
IDD
VIH = 5 V or VIL = 0 V
3.5
6
A
Power Dissipation
PDISS
VIH = 5 V or VIL = 0 V, VDD = 5 V
30
W
Power Supply Sensitivity
PSS
VDD = 5 V ± 10%, code = midscale
±0.02
±0.08
%/%
DYNAMIC CHARACTERISTICS
Bandwidth, 3 dB
BW
RAB = 10 k/50 k/100 k, code = 0x80
600/100/40
kHz
Total Harmonic Distortion
THDW
VA = 1 V rms, VB = 0 V, f = 1 kHz,
RAB = 10 k
0.1
%
VW Settling Time
tS
VA = 5 V, VB = 0 V, ±1 LSB error band
2
s
Resistor Noise Voltage Density
eN_WB
RWB = 5 k, RS = 0
9
nV/√Hz
1
Typical specifications represent average readings at 25°C and VDD = 5 V.
2
Resistor position nonlinearity error, R-INL, is the deviation from an ideal value measured between the maximum resistance and the minimum resistance wiper
positions. R-DNL measures the relative step change from the ideal between successive tap positions. Parts are guaranteed monotonic.
3
VA = VDD, VB = 0 V, wiper (VW) = no connect.
4
Specifications apply to all VRs.
5
INL and DNL are measured at VW with the RDAC configured as a potentiometer divider similar to a voltage output DAC. VA = VDD and VB = 0 V.
DNL specification limits of ±1 LSB maximum are guaranteed monotonic operating conditions.
6
Resistor Terminal A, Resistor Terminal B, and Resistor Terminal W have no limitations on polarity with respect to each other.
7
Guaranteed by design, but not subject to production test.
8
Measured at the A terminal. The A terminal is open circuited in shutdown mode.